Honeywell - Salisbury Electrical Safety Catalog
INSULATING PLASTIC GUARDS/ COVERS
LINE HOSES/ COVERS
ARC FLASH PPE
DIELECTRIC FOOTWEAR
INSULATED JUMPERS
VOLTAGE DETECTORS
INSULATED TOOLS
OUTAGE PROTECTION
SLEEVES
BLANKETS
HISTORY
CONTENT
GROUNDING
SAFETYLINE
HOT STICKS
INSULATORS
GLOVES
20 KV SILICONE STINGER COVERS SALISBURY ADVANTAGE
20 KV SILICONE STINGER COVERS SPECIFICATIONS PHYSICAL PROPERTIES Property
The Salisbury stinger covers SC and SCS series are extruded in EPDM or silicone rubber and designed for field installation over bare conductors. The covers provide electrical insulation and protection for phase to phase and phase to ground flashover that is caused by wildlife contact. Accepted by (RURAL Utility Services) RUS.
Specifications Silicone rubber
Test method
Material
N/A N/A
Color
Gray
Tensile Strength Elongation Durometer Temperature Tear resistant Ozone resistant
600 PSI min
ASTM D-638 ASTM D-412 ASTM D2240
≥200%
HIGH VOLTAGE WILD LIFE OUTAGE PROTECTION CONDUCTOR COVER
60 ±8
-40°C to 200°C
N/A N/A
New silicone stinger covers are suitable for applications up to 20 kV phase to ground. The new cover design offers improved electrical insulation for phase to phase and phase to ground protection. The covers are extruded with a tapered profile specifically designed to overlap onto itself and over the conductor further improving the dielectric properties and conductor protection. The new stinger covers are manufactured using silicone rubber which has excellent high and low temperature properties. They are designed to resist the test of time, sun and weather while keeping assets protected. The stinger cover can be installed without disconnecting the lead wire from the bushing. Stinger covers are available in six diameters and are easily cut down to the length needed in the field.
75 PPI min
No crack @ 40C°(107°F), 70 hrs N/A
UV resistant (ASTM G-26) Flammability rating (provided by material supplier) Comparative tracking Index
Yes
N/A N/A
UL 94 V-0
> 500 V
ASTM D-3638
Low temperature torsional stiffness
Pass
ASTM D 1053-92E
PHYSICAL PROPERTIES Property
Specifications
Test method ASTM D149
Dielectric strength Flashover rating
≥ 300 V/mil (118 kV/cm)
SILICONE STINGER COVER FEATURES • Suitable for applications up to 20 kV phase to ground • Six sizes available & will fit conductors up to 1.25 in dia. • Improved pliability at greater temperature ranges -40° C to 200° C • Excellent UV & Ozone resistance • Unique design profile • Excellent conductor protection and fit • Easy slip on installation, no tool required • Flexibility of covers facilitate overhead installation on tight bends Ideal for substation and distribution applications
Refer to ordering information ASTM D1050 18.2 electrical flashover test
60
61
Enhanced cover profile allows for easy “slip on” installation.
Volumetric resistivity
≥ 1 x 10 14 Ohm/cm
N/A
ORDERING INFORMATION
Flashover Test
I.D. in (mm)
Thickness in (mm)
Quantity ft (m)
Weight Ea. lb (kg)
Item #
Phase to Ground (kV)
Phase to Phase (kV)
34-25SCS-ES 34-50SCS-ES 38-25SCS-ES 38-50SCS-ES 50-50SCS-ES 58-25SCS-ES 58-50SCS-ES 100-25SCS-ES 125-25SCS-ES
0.75 in (19.1 mm) 0.75 in (19.1 mm) 0.375 in (9.5mm) 0.375 in (9.5 mm)
0.2 in (5.08 mm)
20
35
25 ft (7.62 mm) coil
16 lb (7 kg)
—
—
—
50 ft (15.24 mm) coil
—
0.2 in (5.08 mm) 0.2 in (5.08 mm) 0.2 in (5.08 mm)
20 20 20 20 20 20 20
35 35 35 35 35 35 35
25 ft (7.62 mm) coil
10 lb (4 kg) 20 lb (9 kg) 23 lb (10 kg) 26 lb (11 kg) 18 lb (8 kg) 18 lb (8 kg) 13 lb (5 kg)
50 ft (15.24 mm) coil 50 ft (15.24 mm) coil
0.5 in (12.7 mm)
NO AIR GAP OR CUTS ALONG THIS EDGE.
0.625 in (15.9 mm) 0.2 in (5.08 mm) 0.625 in (15.9 mm) 0.2 in (5.08 mm)
25 ft (7.62 mm) coil
50 ft (15.24 mm) coil 25 ft (7.62 mm) coil 25 ft (7.62 mm) coil
1 in (25.4 mm)
0.2 in (5.08 mm) 0.2 in (5.08 mm)
1.25 in (31.8 mm)
Made with FlippingBook - professional solution for displaying marketing and sales documents online