SI SERIES SILICONE INSULATOR Featuring a silicone formulation weathershed material. Salisbury combined the excellent hydrophobic and electrical qualities of silicone with an optimum weathershed design and corrosion resistant fiberglass rod to produce a state-of-the-art insulator which meets or exceeds industry requirements. The insulators were tested in accordance with ANSI C29 and IEC1109. End fittings are hot dipped galvanized high strength carbon steel, providing a 15,000 pound ultimate tensile strength. 100% proof testing ensures trouble-free installation. RUS Accepted.

9502L-EP SILICONE INSULATOR The 9502L-EP-ES Silicone Insulator combines two essential characteristics: Performance and Innovation. The 9502L-EP-ES is the only composite insulator manufactured as a replacement for two 10 in (254 mm) porcelain disks. Installation is limited to horizontal dead-end applications only. Unlike any other insulator on the market, the unique shed design of the 9502L-EP-ES minimizes the material content without compromising electrical or dimensional requirements. End fittings are hot dipped galvanized high strength carbon steel. Must be used as a dead end insulator only. RUS Accepted.

SPECIFICATIONS

9502L-EP-ES

Number of weathersheds

4

L

Length

12.5 in (0.29 m) 5 in (127 mm) 22 in (0.56 m)

Diameter of weathersheds

Leakage distance

Electrical

Critical impulse

189 116

Ratings

Dry, 60 Hz

kV

Wet, 60 Hz

92

SI SERIES INSULATORS SPECIFICATION

Radio

Test, kV ground

20 kV

9501U-SI-ES

9502U-SI-ES

9503U-SI-ES

Max RIV-1000 kHz μ V

Influence

1

Class

DS-15

DS-28

DS-35

Typ. appl-kV, Ø-Ø

27

Number of weathersheds

4

6

8

Ultimate strength-SML

15,000 lb (70 kN)

Length

13.5 in (0.34 m)

17.5 in (0.45 m)

21.3 in (0.54 m)

Net weight

2.8 lb (1.3 kg)

Diameter of weathersheds

3.8 in (97 mm)

3.8 in (97 mm)

3.8 in (97 mm)

Leakage distance Dry arc distance

17.1 in (0.44 m)

26 in (0.66 m)

35.1 in (0.89 m)

8.4 in (0.22 m)

12.13 in (0.31 m)

16 in (0.41 m)

Critical impulse, positive Critical impulse, negative

173 250

217 310 145 115

258 340 168 137

Flash over voltage

Dry, 60 Hz

97 67

Wet, 60 Hz

Test, kV ground

15 kV

25 kV

35 kV

Radio influence

Max RIV-1000 kHz μ V

1

1

uV

Ultimate strength FRP rod diameter Typ. Appl-kV, Ø-Ø

15,000 lb

15,000 lb

15,000 lb

0.73 in (18,63 mm)

0.73 in (18,63 mm)

0.73 in (18,63 mm)

190

191

15

27

35

Net weight

2.6 lb (1.2 kg)

3.1 lb (1.39 kg)

3.5 lb (1.57 kg)