Honeywell - Salisbury Electrical Safety Catalog
INSULATING PLASTIC GUARDS/ COVERS
LINE HOSES/ COVERS
ARC FLASH PPE
DIELECTRIC FOOTWEAR
INSULATED JUMPERS
VOLTAGE DETECTORS
INSULATED TOOLS
OUTAGE PROTECTION
SLEEVES
BLANKETS
HISTORY
CONTENT
GROUNDING
SAFETYLINE
HOT STICKS
INSULATORS
GLOVES
SI SERIES SILICONE INSULATOR Featuring a silicone formulation weathershed material. Salisbury combined the excellent hydrophobic and electrical qualities of silicone with an optimum weathershed design and corrosion resistant fiberglass rod to produce a state-of-the-art insulator which meets or exceeds industry requirements. The insulators were tested in accordance with ANSI C29 and IEC1109. End fittings are hot dipped galvanized high strength carbon steel, providing a 15,000 pound ultimate tensile strength. 100% proof testing ensures trouble-free installation. RUS Accepted.
9502L-EP SILICONE INSULATOR The 9502L-EP-ES Silicone Insulator combines two essential characteristics: Performance and Innovation. The 9502L-EP-ES is the only composite insulator manufactured as a replacement for two 10 in (254 mm) porcelain disks. Installation is limited to horizontal dead-end applications only. Unlike any other insulator on the market, the unique shed design of the 9502L-EP-ES minimizes the material content without compromising electrical or dimensional requirements. End fittings are hot dipped galvanized high strength carbon steel. Must be used as a dead end insulator only. RUS Accepted.
SPECIFICATIONS
9502L-EP-ES
Number of weathersheds
4
L
Length
12.5 in (0.29 m) 5 in (127 mm) 22 in (0.56 m)
Diameter of weathersheds
Leakage distance
Electrical
Critical impulse
189 116
Ratings
Dry, 60 Hz
kV
Wet, 60 Hz
92
SI SERIES INSULATORS SPECIFICATION
Radio
Test, kV ground
20 kV
9501U-SI-ES
9502U-SI-ES
9503U-SI-ES
Max RIV-1000 kHz μ V
Influence
1
Class
DS-15
DS-28
DS-35
Typ. appl-kV, Ø-Ø
27
Number of weathersheds
4
6
8
Ultimate strength-SML
15,000 lb (70 kN)
Length
13.5 in (0.34 m)
17.5 in (0.45 m)
21.3 in (0.54 m)
Net weight
2.8 lb (1.3 kg)
Diameter of weathersheds
3.8 in (97 mm)
3.8 in (97 mm)
3.8 in (97 mm)
Leakage distance Dry arc distance
17.1 in (0.44 m)
26 in (0.66 m)
35.1 in (0.89 m)
8.4 in (0.22 m)
12.13 in (0.31 m)
16 in (0.41 m)
Critical impulse, positive Critical impulse, negative
173 250
217 310 145 115
258 340 168 137
Flash over voltage
Dry, 60 Hz
97 67
Wet, 60 Hz
Test, kV ground
15 kV
25 kV
35 kV
Radio influence
Max RIV-1000 kHz μ V
1
1
uV
Ultimate strength FRP rod diameter Typ. Appl-kV, Ø-Ø
15,000 lb
15,000 lb
15,000 lb
0.73 in (18,63 mm)
0.73 in (18,63 mm)
0.73 in (18,63 mm)
190
191
15
27
35
Net weight
2.6 lb (1.2 kg)
3.1 lb (1.39 kg)
3.5 lb (1.57 kg)
L
Made with FlippingBook - professional solution for displaying marketing and sales documents online