Honeywell - Respiratory Protection Catalogue

Authorised Distributor: Northrock Safety Equipment Pte Ltd

RESPIRATORY PROTECTION CATALOGUE The Right Respiratory Protection Matters

Respiratory Protection

RESPIRATORY > Because Your Protection Matters

Because Your Protection Matters

When it comes to respiratory protection, bulk doesn’t necessarily equal more protection. Comfort plays a large part in respiratory protection compliance. If respirators aren’t comfortable, workers will not wear them or wear them correctly. We’ve put in decades of research and development to engineer premium products that maintain quality and focus on improved fit, comfort, breathability, and reducing worker fatigue over the course of an 8-hour workday. Protection goes beyond personal protective equipment (PPE). Because at the end of the day, we are not just protecting a worker, we are protecting a life.

With workers’ lives at stake, providing quality respiratory protection is critical. As a global leader in respiratory protection, Honeywell offers the most extensive range of single-use masks, reusable facepieces elements, powered air purifying respirators, air supply equipment, as well as self-contained breathing apparatus for a wide range of applications. With over 100 years of experience in respiratory protection, Honeywell concentrates its efforts on developing efficient and comfortable equipment in collaboration with actual users to continuously better meet their needs.

2 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection RESPIRATORY > CONTENT

Content

02 Because Your Protection Matters 04 Know Your Respiratory Safety Needs 05 Making The Best Choice 06 Air-Purified Respirator Reference Chart 07 Disposable Respirators 09 Reusable Respirators 17 N-Series Cartridges, Filter And Accessories 21 Fitting Instructions 23 Powered Air Purifying Respirator (PAPR) 27 Constant Flow Supplied Air Respirator (CF-SAR) 30 Air Supply Systems 33 Escape Solutions 42 Self-Contained Breathing Apparatus (SCBA)

Respiratory Protection Catalogue I sps.honeywell.com I 3

Respiratory Protection

RESPIRATORY > Know Your Respiratory Safety Needs

Know Your Respiratory Safety Needs

When choosing a respirator that is suitable for your work environment, several important factors needs to be taken into account.

HARMFUL SUBSTANCES MAY BE IN THE FORM OF DUSTS, MISTS, FUMES, GASES, VAPORS, OR COMBINATIONS.

B) Selection of filter efficiency (i.e., 95%, 99%, or 99.97%) depends on how much filter leakage can be accepted. Higher filter efficiency means lower filter leakage. • For protection from gases and vapors, use a different respirator type. The type of contaminant and concentration will determine which filter/respirator is required. You need to know the workplace exposure standard for it. • Conduct regular trainings for the need and correct use of respirators. Product training and motivation of users of personal protective equipment is vital to ensure complete understanding of a respiratory protection program.

• Ensure there is sufficient oxygen present in your work environment (please refer to standards or regulations for concentration level details). • Determine the physical and chemical properties of the contaminant – this can be ascertained from the most current Material Safety Data Sheet (MSDS) for the substance concerned, or from other appropriate reference resources. • Determine the concentration of the contaminant in your workplace environment. Lower capacity respirators are only designed to work at lower concentration levels, and you may need to use a different respirator for a higher rate of contaminant concentration. • Assess the working conditions and respirator protection factor. It is recommended to use a filter series (N, R, or P), depending on the contaminant and its concentration level. A) The selection of N, R, and P-series filters depends on the presence or absence of oil particles. - If no oil particles are present in the work environment, use a filter of any series (i.e., N, R, or P-series). - If oil particles (e.g., lubricants, cutting fluids, glycerine, etc.) are present, use a R or P-series filter. N-series filters cannot be used if oil particles are present.

- If oil particles are present and the filter is to be used for more than one work shift, use only a P-series filter.

4 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection

RESPIRATORY > MAKING THE BEST CHOICE

MAKING THE BEST CHOICE Workers’ health is our priority. That’s why Honeywell has designed respirators that not only protect workers from airborne contaminants, but are comfortable and easy to use. This ensures our products are worn day-in, day-out with confidence. Honeywell respiratory solutions include disposable respirators, reusable respirators and Self-Contained Breathing Apparatus (SCBA) products all manufactured to protect workers in a variety of industries including: oil and gas, construction, mining, disaster and emergency services, fire fighting, chemicals and paint, science, and health. When selecting a respirator, consider the chemical and physical properties of the contaminant, the toxicity and concentration of the hazardous material, and the amount of oxygen present.

INDUSTRIAL HAZARD

OXYGEN DEFICIENCY

TOXIC CONTAMINANT

FIRE

SCBA

SCBA

Known Concentration

Unknown Concentration

PD-SAR with aux SCBA

SCBA

Not IDLH

IDLH

PD-SAR with aux SCBA

Gases / Vapors & Particulates

SCBA

Particulates

Gases & Vapors

PD-SAR with aux SCBA

Cartridge Respirator with Particulate Filter

Disposable Respirator

Cartridge Respirator

Dust / Fume / Mist Filter Respirator

CF-SAR

CF-SAR

PAPR

PAPR

PAPR

Key Terms SCBA PD-SAR

Self-Contained Breathing Apparatus

Pressure Demand Supplied Air Respirator Immediately Dangerous to Life and Health

IDLH PAPR

Powered Air Purifying Respirator

CF-SAR

Constant Flow Supplied Air Respirator

Dust Mist Fume

Mechanically generated solid particle suspended in air. i.e. flour grain, sanding, quarrying etc.

Mechanically generated liquid particle suspended in air

Thermally generated solid particle which vaporizes then solidifies and drops down. i.e. welding, furnacing, etc.

Gas/Vapor

Neither solid nor liquid at room temperature

Respiratory Protection Catalogue I sps.honeywell.com I 5

Respiratory Protection RESPIRATORY > AIR-PURIFIED RESPIRATOR REFERENCE CHART AIR-PURIFIEDRESPIRATOR REFERENCE CHART

HALF MASK

FULL FACE MASK

550030

770030

RU850001

54001

RU65001

76008A

N75001L Organic Vapor (OV)

N75002L Acid Gas (AG)

Catridge with P100 Combination

N75003L Organic Vapor (OV) / Acid Gas (AG)

N75004L Ammonia (AM)/ Methylamine (MA)

75SCL Defender (Multi-contaminant)

N750036

N750052L Mercury (Hg)/ Chlorine Gas (CI)

N7506N95 N95 Pre-filter

N7506R95 R95 Pre-filter

N750037 Filter Cover and Holder Kit

75FFP100 P100 Pancake Filter

75FFP100NL P100 Pancake Filter w/ nuisance level OV AG Ozone

N750035 Filter Adapter

7580P100 P100 Hard Shell Filter

6 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection RESPIRATORY > DISPOSABLE RESPIRATORS

Honeywell DISPOSABLE respirators

Honeywell H801 Plus Cup-Shape Disposable Respirator Cup-shape mask indicated for use with particulate aerosols free of oil, providing safe and comfortable particulate protection. • Prevents non-oil particles and provides filtering efficiency that exceeds 95% • Large breathing area effectively improves breathing resistance • Large breathing chamber accelerates airflow and effectively reduces dead space • Arc-shaped stiffeners prevent extrusion and deformation to improve stability and safety during wear • Durable aluminium nose clip is adjustable and bend-resistant • The sealing material used for the nose pad provides pressure relief on the nose bridge, and offers excellent fit, softness, and comfort • The latex-free elastic head straps withstand wear and tear and reduce pressure on the head, ensuring long hours of use • NIOSH N95 approved particulate respirator • DOSH SIRIM Approval No.: JKKP/2022/12-01/06/00022/0001 (DC100H801N95); JKKP/2022/12-01/06/00022/0003 (DC100H801N95V) Honeywell H910 Plus Flat-Fold Disposable Respirator Flat-fold mask indicated for use with particulate aerosols free of oil, providing safe and comfortable particulate protection. • Prevents non-oil particles and offers filtering efficiency that exceeds 95% • Comes with Honeywell’s anti-counterfeiting filter material that blocks fine particles • The nose clip is made of a high-strength plastic composite metal that provides enhanced bending resistance capacity, better fit and improved protection without metal exposure • The advanced sealing material used for the nose pad offers excellent fit, softness, and comfort, relieving the nose bridge’s pressure • Its large size provides ample breathing space inside for greater comfort • The latex-free elastic head straps reduce the pressure on the head, providing more comfort for long time use • NIOSH N95 approved particulate respirator • DOSH SIRIM Approval No.: JKKP/2022/12-01/06/00022/0002 Part No. Description PACKAGING DF300H910N95 H910 Plus N95 disposable mask, head strap 50 each per box, 12 boxes per case

DF300H910N95

DC100H801N95

Part No.

Description

PACKAGING

DC100H801N95

H801 Plus cup-shape mask, head-strap

20 each per box, 8 boxes per case

DC100B801N95V

H801 Plus cup-shape mask with valve, head-strap

10 each per box, 8 boxes per case

DC100H801N95V

Respiratory Protection Catalogue I sps.honeywell.com I 7

Respiratory Protection

RESPIRATORY > DISPOSABLE RESPIRATORS

DC365 Surgical N95 Respirator Honeywell DC365 Surgical N95 Respirator is an easy-to-don and doff, high fluid-resistant surgical respirator designed for clinician satisfaction across the spectrum of care. • Fluid-resistant ASTM F1862 160 mmHg • NIOSH-certified Surgical N95 (NIOSH 42 CFR 84) • FDA registered • Designed with comfort in mind • Dye-free and non-sensitizing • Materials feel smooth and soft next to the skin • Flexible, light-weight construction conforms gently to the face, minimizing pressure points • Durable, dual-welded straps are easy to don and doff, and provide a secure and comfortable fit • Adjustable nosepiece for a customizable fit • Multi-layer absorption media designed for lower breathing resistance • One size, cup-shape mask with spacious breathing chamber SAF-T-Fit® Plus Disposable Respirator Molded cup disposable respirators that offer the most variety in protection and comfort. • Molded cup design • Incorporates humidity-resistant filter media • Low breathing resistance • Lightweight design • Durable suspension straps • Optional boomerang nose seal or full-face seal for secure and comfort fit • Organic Vapor or Acid Gas nuisance available in N95 and P95 models • N95, N99 or P95 protection to choose from • Nose clip is color-coded for visible size recognition • Packaged to maintain integrity of product in work environment Part No. Description PACKAGING DC365N95HC Honeywell DC365 Surgical N95 Respirator

DC365N95HC

20 each per box, 10 boxes per case

14110403

Part No.

Description

PACKAGING

14110394 N1125 N95 with Boomerang Nose Seal and Valve. Size M/L

20 each per box, 10 boxes per case

N1125-OV N95 (Nuisance OV) with Boomerang Nose Seal and Valve. Size M/L N1125-AG N95 (Nuisance AG/HF) with Boomerang Nose Seal and Valve. Size M/L

14110397

10 each per box, 10 boxes per case

14110400

10 each per box, 10 boxes per case

14110403 N1139 N99 with Full Sealing Flange and Valve. Size M/L

10 each per box, 10 boxes per case

14110397

14110428 P1135 P95 (Nuisance OV) with Full Sealing Flange and Valve. Size M/L

10 each per box, 10 boxes per case

P1135-1 P95 (Nuisance OV) with Full Sealing Flange and Valve. Size M/L

14110430

10 each per box, 10 boxes per case

8 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection RESPIRATORY > REUSABLE RESPIRATORS

reusable respirators

Honeywell reusable respirators include innovative features and design, providing great protection at a competitive price.

Reusable respirators use replaceable filters to clean the air when combined with a half-facepiece, full-facepiece, or head covering. Wearers are protected from finely divided solids and liquid matter (particulates), or gases and vapours from the air.

Filters are available to protect against contaminants such as organic vapours, acid gases, sulphur dioxide and ammonia.

PRODUCT OVERVIEW

COMFORTABLE MATERIALS Manufactured from lightweight and high quality material, providing durability and comfort. RANGE OF SIZES All models offer a variety of mask sizes to allow for different face shapes and sizes. EASY TO BREATHE Large inhalation ports on the full face mask reduce breathing resistance, improving fit and comfort.

BACKUP SERVICES Complete range of replacement

parts provides significant operational cost savings.

MULTI-PURPOSE Honeywell facepieces are multi purpose for easy conversion from APR, PAPR or SAR, to provide protection against almost any contaminant and concentration level.

Respiratory Protection Catalogue I sps.honeywell.com I 9

Respiratory Protection RESPIRATORY > REUSABLE RESPIRATORS

Honeywell North® RU8500 Half Mask Improve productivity and maintain compliance with the Honeywell North RU8500 Series half mask. • Equipped with a speech diaphragm for better speech clarity – eliminating the need for workers to leave the workspace or doff the mask to communicate • Made from soft, flexible silicone to provide workers with a comfortable fit for hours of use • Dual sealing flange provides an excellent facepiece seal • Unique optional of a diverter exhalation valve cover to direct exhaled breath downward, ideal for painting/coating/sealing • NIOSH approved with PAPR and Supplied Air to offer flexibility in the workplace

RU85001

Part No.

Description

PACKAGING

RU85001S

RU8500 Half mask with speech diaphragm, Royal Blue. Size Small.

1 each per box, 12 boxes per case

RU85001M RU8500 Half mask with speech diaphragm, Royal Blue. Size Medium.

1 each per box, 12 boxes per case

RU85001L

RU8500 Half mask with speech diaphragm, Royal Blue. Size Large.

1 each per box, 12 boxes per case

7700 Series Half Mask The benchmark in half masks, designed to provide maximum comfort, fit and performance. Made from 100% medical grade silicone, latex free. Cradle suspension features woven straps that provide for maximum mobility without sacrificing support. • Easily converts to PAPR or supplied air respirator • Lower head straps stretch and move with the worker for more comfort without pulling on the facepiece • Upper head straps have minimum give to provide secure support • Various thickness in sealing area for improved comfort and support - more support around the chin area and more flexibility on the nose bridge • Wide contoured sealing area for great fit • NIOSH approved with PAPR and Supplied Air to offer flexibility in the workplace

770030

Part No.

Description

PACKAGING

770030S

7700 Half mask medical grade silicone. Size Small.

1 each per box, 12 boxes per case

770030M

7700 Half mask medical grade silicone. Size Medium.

1 each per box, 12 boxes per case

770030L

7700 Half mask medical grade silicone. Size Large.

1 each per box, 12 boxes per case

10 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection

RESPIRATORY > REUSABLE RESPIRATORS

5500 Series Half Mask The North 5500 Series half mask is the economical option that still provides many of the same features found in premium masks. Flexible and durable half mask made from elastomer, latex free. Its ergonomic design and improved suspension system fit perfectly on the head and face, providing high levels of comfort and performance. • Easily converts to PAPR or supplied air respirator • Low “dead air” space limits re-breathing of exhaled air for increase comfort and worker productivity • Lower head straps stretch and move with the worker for more comfort without pulling on the facepiece • Upper head straps have minimum give to provide secure support • Various thickness in sealing area for improved comfort and support - more support around the chin area and more flexibility on the nose bridge • Wide contoured sealing area provides great fit • NIOSH approved with PAPR and Supplied Air to offer flexibility in the workplace

550030

Part No.

Description

PACKAGING

550030S

5500 Half mask elastomeric. Size Small.

1 each per box, 12 boxes per case

550030M

5500 Half mask elastomeric. Size Medium.

1 each per box, 12 boxes per case

550030L

5500 Half mask elastomeric. Size Large.

1 each per box, 12 boxes per case

Respiratory Protection Catalogue I sps.honeywell.com I 11

Respiratory Protection

RESPIRATORY > REUSABLE RESPIRATORS

Honeywell NORTH® HM500 SERIES HALF MASK

The Future of Respiratory Protection

WHY HM500? Working in oil & gas, pharmaceutical, manufacturing or metal industries inherently involves the risk of inhaling harmful particles, vapors and gases, and wearing respiratory protection is not always comfortable. With our long standing expertise in respiratory protection and a deep understanding of worker needs, Honeywell North has redefined the notion of comfort, efficiency and safety. The lightweight design, the soft material, the easy operation features and the dropdown function makes HM500 a respiratory solution workers will want to wear. The HM500 mask is also available in a drop-down version for better usability. BREAKTHROUGH COMFORT • Lighter than other similar masks with cartridges available on the market • Softer material for better touch and seal with skin, for long-time use • Professional design for universal fit Welcome to the new dimension of safety and comfort: The Honeywell North® Half Mask 500 (HM500) Series. Engineered as a lightweight, durably soft half mask, HM500 ensures better comfort and convenience – particularly for extended wear.

INDUSTRIES & APPLICATIONS • Oil & Gas – chemical processing • Pharmaceutical –

maintenance, laboratories • General Manufacturing – assembling, painting • Metal Industry – welding applications • Construction – respirable crystalline silica

HM501, non-drop-down version

TOP NOTCH EFFICIENCY • Advanced over-molding manufacturing and design made for intuitive assembly and disassembly • Drop-down function replaces need to doff hardhat or earmuff for quick work break

ON THE JOB SAFETY • Easy cleaning and maintenance • Both maintain effective seal all shift long • Both are PPE compatible • Both maintain good field of view

HM502, drop-down version

12 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection

RESPIRATORY > REUSABLE RESPIRATORS

COMPATIBLE WITH N-SERIES FILTERS & CARTRIDGES Honeywell’s N-Series filters and cartridges are quick and easy to attach to any of our APR reusable masks, including the HM500 Series.

PRODUCT OVERVIEW

INCREASED COMFORT The N-Series filters and cartridges are lightweight (20% lighter than the T-series), making it more comfortable to wear during long shifts. CLEAR LINE OF SIGHT The cartridges have a low profile and do not intrude into the work zone, enabling the worker to see everything he or she needs to see, even when doing close-up activities.

SUITED FOR MANY ENVIRONMENTS Applicable to explosive working environments, including Oil & Gas, Pharmaceuticals, General Manufacturing, Construction, and Welding. EASY FIT CHECKING No matter how small your hands might be, you can achieve an easy user seal check without struggling or using adapters.

Respiratory Protection Catalogue I sps.honeywell.com I 13

Respiratory Protection

RESPIRATORY > REUSABLE RESPIRATORS

WHY DROP-DOWN VERSION OF HM500 SERIES? The drop-down option allows workers to put down the mask without removing hard hats, ear muffs or eyewear, while the non-drop-down option is great for more challenging work environments that need fixed, all-shift protection. To remove the mask, just release the buckle behind the neck. Once the buckle is released, tilt the nose cup upwards gently while pulling the half mask down. Thus, it will slide down smoothly without needing to take the head harness off.

Drop-down Usage Remove mask without taking other PPE off.

Drop-down System Straps are pulled through the mask, ensuring an easy slide.

ORDERING INFORMATION

SKU

DESCRIPTION

STANDARD VERSION HM501TS

HM500 Small Elastomer Threaded Fixed

HM501TM

HM500 Small Elastomer Threaded Fixed

HKM501TL

HM500 Large Elastomer Threaded Fixed

DROP-DOWN VERSION HM502TS

HM500 Small Elastomer Threaded Fixed Drop Down

HM502TM

HM500 Medium Elastomer Threaded Fixed Drop Down

HM502TL

HM500 Large Elastomer Threaded Fixed Drop Down

REPLACEMENT PARTS 770018

Exhalation Valve

HM5RP06

Inhalation Valve

HM5RP05

Headband Assembly

HM5RP05D

Drop-Down Headband Assembly

HM5RP04

Threaded Gasket

14 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection

RESPIRATORY > REUSABLE RESPIRATORS

5400 Series Full Facepiece Ideal workhorse respirator for subcontractors and other occasional users, the best value you can find in a full facepiece. • Wide sealing area fits a variety of facial types • Facepiece is made from latex free, thermoplastic elastomer that fits comfortably • Thermoplastic elastomer nose cup reduces slipping for a secure fit • Polycarbonate lens with 200° wide field of vision maximizes peripheral visions plus downward view; meets ANSI Z 87 for high impact • Four-strap head harness offers secure fit • Threaded cartridge connector secures equipment to avoid accidental disconnections • Available with welding adapter • Can be adapted to PAPR or CF-SAR, eliminating the need to fit test workers on several respirators • NIOSH approved with PAPR and Supplied Air to offer flexibility in the workplace

54001S

Part No.

Description

PACKAGING

54001

5400 Full facepiece elastomer. Size Medium/Large.

1 each per case

54001S

5400 Full facepiece elastomer. Size Small.

1 each per case

54001W

5400 Full facepiece elastomer with welding attachment. Size Medium/Large.

1 each per case

54001LSW 5400 Full facepiece elastomer with welding attachment. Size Small.

1 each per case

RU6500 Series Full Facepiece The North RU6500 silicone full facepiece provides all day comfort at a great price. • Silicone seal provides excellent facepiece seal, creating a barrier against contaminants • Silicone nose cup is soft and comfortable for all day wear • Polycarbonate lens with 200° wide field of vision maximizes peripheral visions plus downward view; meets ANSI Z 87 for high impact • Five-point strap option includes center strap to help position and hold the mask for a more secure fit by offering quick, easy adjustments • Industrial mesh headnet option provides another choice for user comfort preference - can be used under hard hat • Threaded cartridge connector secures cartridges and filters to avoid accidental disconnections • Can be adapted to side mount CF-SAR, front mount CF-SAR, side mount PAPR and front mount PAPR, eliminating the need to fit test workers on several respirators • NIOSH approved with PAPR and Supplied Air to offer flexibility in the workplace

RU65001

Part No.

Description

PACKAGING

RU65001S

RU6500 Full Facepiece with 5-point head strap. Size Small.

1 each per case

RU65001M RU6500 Full Facepiece with 5-point head strap. Size Medium.

1 each per case

RU65001L

RU6500 Full Facepiece with 5-point head strap. Size Large.

1 each per case

Respiratory Protection Catalogue I sps.honeywell.com I 15

Respiratory Protection RESPIRATORY > REUSABLE RESPIRATORS

7600 Series Full Facepiece The most comfortable mask available, delivering superior fit and durability. • Integrated medical grade silicone nose cup and dual flange face seal are soft and comfortable for all day wear • Polycarbonate lens with 200° wide field of vision maximizes peripheral visions plus downward view; meets ANSI Z 87 for high impact • Five-strap head harness includes center strap to help position and hold the mask for a more secure fit • Kapton® speech diaphragm clarifies conversations, enhancing safety and other communication • Dual flange sealing area provides extra layer of protection to prevent leaks • Threaded cartridge connector secures equipment to avoid accidental disconnections • Can be adapted to PAPR or CF-SAR, eliminating the need to fit test workers on several respirators • Available with welding adapter • NIOSH approved with PAPR and Supplied Air to offer flexibility in the workplace

760008A

Part No.

Description

PACKAGING

760008A

7600 Full facepiece premium silicone. Size Medium/Large.

1 each per case

760008AS

7600 Full facepiece premium silicone. Size Small.

1 each per case

760008AW 7600 Full facepiece premium silicone with welding attachment. Size Medium/Large.

1 each per case

760008ASW 7600 Full facepiece premium silicone with welding attachment. Size Small.

1 each per case

16 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection RESPIRATORY > N-SERIES CARTRIDGES, FILTER AND ACCESSORIES Honeywell N-Series Cartridges And Filter/Cartridge Combinations Have Lost The Bulk!

1

2

3

4

Honeywell N-Series are compatible with the current 5500, 7700, RU8500, 5400, 7600 and RU6500 Series facepieces and have the same long service life workers have counted on

Threaded connectors securely fasten to our North half masks and full facepieces, making them easy to attach without worry of them popping off accidentally

Easy user seal check – workers with petite hands will appreciate this improvement, no more struggling or using adapters to achieve a negative check

Redesigned profile is 7% lower, increasing workers’ field of vision, even when doing close up detail work

Respiratory Protection Catalogue I sps.honeywell.com I 17

Respiratory Protection RESPIRATORY > N-SERIES CARTRIDGES, FILTER AND ACCESSORIES

N-SERIES GAS AND VAPOR CARTRIDGES Part No. Description PACKAGING

Defender™ Multi-Purpose: NIOSH approved for use against Organic Vapors, Ammonia, Methylamine, Formaldehyde and Acid Gases (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Sulfide, Chlorine Dioxide, Hydrogen Fluoride)

75SCL

18 pairs per case

75SCL

N75001L

Organic Vapor: NIOSH approved for use against Organic Vapors

N75001L

18 pairs per case

Acid Gas Cartridge: NIOSH approved for use against Acid Gases (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Fluoride and Chlorine Dioxide) and Formaldehyde Organic Vapor & Acid Gases: NIOSH approved for use against Organic Vapors and Acid Gases (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Fluoride and Chloride Dioxide) Ammonia & Methylamine: NIOSH approved for use against Ammonia and Methylamine Mercury Vapor Cartridge with ESLI: Mercury Vapor and Chlorine with End-of-Service Life Indicator (ESLI) for Mercury Vapor

N75002L

18 pairs per case

N75003L

18 pairs per case

N75002L

N75003L

N75004L

18 pairs per case

N750052L

18 pairs per case

N75004L

N750052L

N-SERIES COMBINATION GAS AND VAPOR CARTRIDGES WITH P100 PARTICULATE FILTERS Part No. Description PACKAGING

Defender™ Multi-Purpose with P100: Approved for use against Organic Vapors, Ammonia, Methylamine, Formaldehyde and Acid Gases (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Sulfide, Chloride Dioxide, Hydrogen Fluoride); and 99.97% filter efficiency for all particulates Organic Vapor with P100: Approved for use against Organic Vapors and 99.97% filter efficiency for all particulates Acid Gas with P100: Approved for use against Acid Gases (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Sulfide (escape), Chloride Dioxide, Hydrogen Fluoride); and 99.97% filter efficiency for all particulates Organic Vapor and Acid Gas with P100: Approved for use against Organic Vapors and Acid Gases (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Sulfide, Chloride Dioxide, Hydrogen Fluoride); and 99.97% filter efficiency for all particulates Ammonia & Methylamine with P100: NIOSH approved for use against Ammonia and Methylamine; and 99.97% filter efficiency for all particulates Mercury Vapor Cartridge with ESLI, with P100: Mercury Vapor and Chlorine with End-of-Service Life Indicator (ESLI) for Mercury Vapor; and 99.97% filter efficiency for all particulates

75SCP100L

7581P100L

75SCP100L

12 pairs per case

7581P100L

12 pairs per case

7582P100L

12 pairs per case

7582P100L

7583P100L

7583P100L

12 pairs per case

7584P100L

12 pairs per case

75852P100L

12 pairs per case

7584P100L

75852P100L

18 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection

RESPIRATORY > N-SERIES CARTRIDGES, FILTER AND ACCESSORIES

N-SERIES PARTICULATE FILTERS Part No. Description

PACKAGING

P100 Filter: 99.97% efficiency for all particulates

7580P100

72 pairs per case

7580P100

Flexible, Low Profile P100 Filter: For use under welding helmets; 99.97% efficiency for all particulates

75FFP100

50 pairs per case

Flexible, Low Profile P100 Filter with Odor Relief: For use under welding helmets; 99.97% efficiency for all particulates, plus relief from odors caused by nuisance levels of organic vapors, acid gases and ozone

75FFP100NL

50 pairs per case

75FFP100

N95 Pad Filter: 95% filter efficiency for non-oil based aerosol particulates

10 pcs per pack, 120 pcs per case

7506N95

R95 Pad Filter: 95% filter efficiency for particulates containing oil-based aerosols, with an 8-hours service life

10 pcs per pack, 120 pcs per case

7506R95

75FFP100NL

7506R95

Backpack Adaptor The Honeywell Backpack Adaptor relocates cartridges and filters out of the work zone, placing them on the user’s back. This also reduces weight of the mask. Adapts easily to Honeywell Air Purifying Respirators, by screwing securely to face piece cartridge connectors. • Keeps cartridges out of the contaminant zone for improved longevity • Provides greater worker comfort and acceptance • Delivers lower operating costs as filters are replaced less often

Part No.

Description

PACKAGING

Backpack Adapter for use with North 5500, North 7700 and Honeywell RU8500 series half masks; cartridges moved to the back for a lower profile to fit under welding helmet faceshields and to keep cartridges away from paint spray

1 each per case

BP1002

BP1002

Respiratory Protection Catalogue I sps.honeywell.com I 19

Respiratory Protection

RESPIRATORY > N-SERIES CARTRIDGES, FILTER AND ACCESSORIES

ACCESSORIES Part No. Description PACKAGING

Assembly for Filters: Assembly for filters includes two (2) N750027 covers and two (2) N750038 filter support to attach filter pads to gas and vapor cartridges Black Shower Cap: For use with N-Series low profile cartridge/filter combinations and 7580P100. Deflects moisture during decontamination shower, and sparks and slag during welding and grinding

N750036

10 pairs per case

N750036

N750029

N750029

96 each per case

Assembly for Filters: Assembly for filters includes two (2) N750027 covers and two (2) N750015 filter holders to attach filter pads to facepiece

N750037

10 pairs per case

Low Profile Filter Adapter: Allows user to stack the 75FFP100 or 75FFP100NL on an N-Series cartridge, converting the filter to a P100 pad filter

6 ampoules per packet, 1 packet per case

N750035

193170

BITREX ® FIT TEST KITS AND REPLACEMENT PARTS

Bitrex Qualitative Fit Test Kit. Includes sensitivity and fit test solutions, sensitivity and fit test nebulizers, fit test hood, 2 sets of replacement nebulizer inserts, 1 fit test DVD and 1 CD with fit test forms and user instructions

193170

1 each per case

6 ampoules per packet, 1 packet per case 6 ampoules per packet, 1 packet per case

193171

Replacement fit test solution for 193170

193171

193172

193172

Replacement sensitivity solution for 193170

193107

Replacement hood for 193170 Bitrex® Fit Test Kits

FIT TEST ADAPTERS

Quantitative fit test adapter for fit testing all facepieces using N-Series filters and cartridges

770021

COVER LENSES

80836A

Peel-away cover lens, clear, for North 5400, 7600 and CF7800 series full facepieces

3 sheets per set, 5 sets per pack

80836A

Peel-away cover lens, clear, for RU6500 facepieces and the Opti-Fit Tactical Mask

702028-H5

25 pcs per box

702028-H5

20 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection

RESPIRATORY > FITTING INSTRUCTIONS

FITTING INSTRUCTIONS

Honeywell reusable respirators include innovative features and design, providing great protection at a competitive price.

FITTING CUP RESPIRATORS

FITTING FLAT FOLD RESPIRATORS

1

2

3

1

2

3

4

5

1 Hold respirator cup in your hand, allowing head-straps to hang freely. 2 Hold respirator under the chin with the nose-piece facing outwards. Place respirator on your face ensuring that the lower part of the respirator is positioned under your chin. Pull the lower head-strap over your head and place it around the neck below the ears. Holding the respirator against the face with one hand, pull the top head-strap over your head and position it above the ears, around the crown of the head. 3 Mold the nose area to face shape, running the finger tips of both hands from the top of the nose-piece down both sides while pressing inward. Always use both hands.

1 Open respirator by pushing slightly on both sides. 2 Pre-form the nose-bridge. 3 Place the respirator under the chin with chin-flap fully open. Holding the respirator against the face, place the lower head-strap around the neck below the ears and the top head-strap above the ears. 4 Correctly donned respirator. 5 Mold nose area to the shape of the face by pinching the nose-bridge from the top to the bottom. Make sure that the chin-flap is open and secure around the chin area.

FIT-CHECK Place both hands over the respirator. If the respirator is not fitted with an exhalation valve, exhale sharply; if the respirator is fitted with an exhalation valve, inhale sharply. If leaks around the edge are detected, re-adjust the head-straps and/or the nose-piece. Repeat the procedure until a satisfactory face fit has been achieved. Important! If the headbands are too loose, you can increase the tension by tying a small knot in the headband.

Respiratory Protection Catalogue I sps.honeywell.com I 21

Respiratory Protection RESPIRATORY > FITTING INSTRUCTIONS

For optimum protection against airborne hazards, your respirator must be fitted correctly. Follow the instructions to achieve the best result.

FIT-TESTING There are two types of facial fit-tests.

FITTING REUSABLE RESPIRATORS 2 1

Qualitative fit-testing is a simple pass/fail test based upon the user’s subjective assessment of the leakage, via the face seal region, of a test agent. Quantitative fit-testing uses equipment (usually a Portacount machine) to measure the efficiency of a respirator in preventing materials in the atmosphere from entering a user’s breathing zone. The Bitrex Fit Test Kit is the most commonly used and is suitable for testing both disposable and reusable respirators fitted with a particulate filter.

4

3

1 Loosen the elastic band without completely pulling the band out of the slots in the crown suspension. 2 Pull gently on the lower neck strap, creating a large loop. Put lower neck strap loop over the head. 3 Place the respirator to the face, covering the mouth and nose. (The narrow part of the facepiece should be over the nose.) Pull the crown suspension over the head and adjust its placement until it is comfortable. 4 Using both hands, grasp the free ends of the elastic band and gently pull the elastic straps away from your face until the respirator is snug and seated comfortably. Be sure the neck strap is flat and smooth against the back of the neck. To tighten the neck strap, make intermediate adjustments at the straps as they exit the top slots on the yoke. Gently pull the free ends to make final adjustments and secure a comfortable fit of the respirator to your face.

22 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection POWERED AIR PURIFYING RESPIRATOR (PAPR)

Respiratory Protection Catalogue I sps.honeywell.com I 23

Respiratory Protection RESPIRATORY > POWERED AIR PURIFYING RESPIRATOR (PAPR) POWERED AIR PURIFYING RESPIRATOR (PAPR)

The Honeywell North® Primair™ 700 (PA700) Series PAPR is engineered to be ergonomic, efficient, and effortless to get workers on the job faster and keep them comfortable and productive. The PA700 Series PAPR offers convenience, comfort, confidence, and connectivity — all day, every day.

INDUSTRIES & APPLICATIONS • Pharmaceutical Development* • Manufacturing (silica dust) • Abatement • Construction • Hospital labs (chemotherapy drug mixing and infectious disease) Meets the requirements of NIOSH CFR 84 when assembled from components listed on the NIOSH approval label included with the product. * Does not include intrinsically safe.

During the engineering phase for the PA700 Series, Honeywell consulted PAPR users and safety managers to understand their vision of ideal PAPR features and functionality. Feedback indicated a need for improved ergonomics, cleanability, and reliability. Honeywell responded to this feedback by developing a PAPR with a thoughtful design — made for superior comfort, safety, and easy operation and maintenance so users can work hard and breathe easy.

CONVENIENCE Honeywell understands the need to get workers on the job fast and keep them productive.That’s why the PA700 Series PAPR was designed to be easy to use and incorporates convenient features. The PA700 Series is easy to assemble with components that lock into place with little effort. Controls are easy to operate — even when wearing gloves. The easy-to-clean, smooth surfaces take just minutes to wipe down at the end of a long day.

COMFORT With Personal Protective Equipment (PPE), safety is the priority — but, comfort is also a must. The PA700 Series was designed with a focus on ergonomics so workers stay comfortable for longer, which increases productivity by reducing the need for breaks or adjustments to equipment. On-demand airflow control helps keep workers cool throughout their shifts. Additional accessories are available to further enhance comfort.

CONFIDENCE Workers who perform their jobs in high-risk environments face hazards on a daily basis. Developed with safety and compliance in mind, the PA700 Series offers employers the confidence that their workers are protected from hazards. The integrated and streamlined design is reliable and durable. Components lock into place so that workers feel safer and can focus on the job, not their equipment.

24 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection RESPIRATORY > POWERED AIR PURIFYING RESPIRATOR (PAPR) PUSH, TWIST, CLICK, AND GO

For the worker who uses a PAPR daily, the Honeywell North PA700 Series makes it easy. The integrated system is streamlined, easy to use, and quick to assemble. With components that lock into place, workers can get on the job quickly and feel safer. Plus, the ergonomic design keeps them comfortable during long shifts, which maximizes productivity.

PRODUCT OVERVIEW

ADJUSTABLE AIRFLOW Three air speeds to enhance user comfort.

THREE ALARMS— VISUAL, AUDIO, AND VIBRATORY Keeps workers safer with intuitive low battery and low airflow notifications.

EFFICIENT KEYPAD Illuminated, easy-to-read display; large buttons for easy operation - even when wearing gloves.

SMART BREATHING TUBE CONNECTION

Twist-and-lock connector angles the tube away from the back; automatically detects between tight- and loose-fitting hoses and adjusts the airflow accordingly.

ERGONOMIC BELT Carefully chosen shape and materials distribute the weight of the PAPR and help keep it from slipping. ADJUSTABLE STRAPS Adjust for customized fit; available in standard industrial nylon or easy-to-clean PVC. COMFORT PAD Rests on lower back and cushions impact for all-day use.

OPTIONAL FILTER COVER Protects the filter from impacts and during decontamination showers; smooth design is easy to wipe clean. CARTRIDGE/ FILTER CONNECTION Allows filter or cartridge/ filter combination to lock into place with a quarter turn, assuring workers they are secure and safer.

LIGHTWEIGHT BREATHING TUBES Highly flexible, corrugated hose for freedom of movement.

SIDE-MOUNTED BATTERY Contained in housing on five (5) sides and locks into place to reduce accidental disconnections.

Respiratory Protection Catalogue I sps.honeywell.com I 25

Respiratory Protection RESPIRATORY > POWERED AIR PURIFYING RESPIRATOR (PAPR)

ORDERING INFORMATION

1. SELECT YOUR PA700 SERIES CONNECTED PAPR BLOWER ASSEMBLY PA701HE

Assembly includes connected blower, battery, battery charger, comfort pad, nylon belt, and bonus P100 filter and optional filter cover

PA701

Assembly includes connected blower, battery, battery charger, comfort pad, and nylon belt

PA701HED

Assembly includes connected blower, battery, battery charger, and Decon belt

Assembly includes connected blower, battery, battery charger, decontamination belt, P100 HEPA filter, filter cover, 34 in straight breathing tube and Medium size loose-fitting head cover and adjustable headgear Assembly includes connected blower, battery, battery charger, decontamination belt, P100 HEPA filter, filter cover, 34 in straight breathing tube and Universal size bibbed hood

PA701HED-101

PA701HED-111

2. SELECT YOUR HOOD OR FACEPIECE PA100 SERIES HEAD COVERS & HOODS HALF MASK

FULL FACEPIECES

WELDING FULL FACEPIECES PA900 SERIES HEADTOPS

PA101S, M

550030S, M, L

54001, S

760008AW, SW

PA911

PA111

770030S, M, L

760008A, S

54001W, SW

PA921

PA121

———

RU65001S, M, L

———

PA921DS, PA921DL

PA131

———

RU65002S, M, L

———

PA922

PA141

———

———

———

PA923*

3. SELECT YOUR BREATHING TUBE PA031, PA031L

Straight Breathing Tube, Short, for Primair Hoods, 34», Straight Breathing Tube, Long, for Primair Hoods, 40»

PA032

Breathing Tube for use with PA900* Series Headtops, 22»

PA033

Straight Breathing Tube for Primair Hoods for use with Backpack PA761, 18”

PA034, PA034L

Y-Shape Breathing Tube for tight-fitting facepieces, 34”, Y-Shape Breathing Tube for tight-fitting facepieces, 40”

4. SELECT YOUR CARTRIDGE OR FILTER PA7HE

P100 High Efficiency Particulate Air-Purifying (HEPA) filter** (5/box)

PA7OVHE

Organic Vapor with High Efficiency Particulate Air-Purifying (HEPA) filter

Organic Vapor, Acid Gas [Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Fluoride, Chlorine Dioxide, Hydrogen Sulfide], with High Efficiency Particulate Air-Purifying (HEPA) filter Multipurpose Cartridge with HEPA filter: [Organic Vapor, Acid Gas (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Fluoride, Chlorine Dioxide, Hydrogen Sulfide)], Ammonia, Methylamine, Formaldehyde, with High Efficiency Particulate Air-Purifying (HEPA) filter

PA7OVAGHE

PA7DEHE

PA7PR

Pre-filter for PA700 PA7HE HEPA filter (10/box)

5. SELECT YOUR ACCESSORIES PA751A

Comfort Pad

PA71A1, PA71A2

Cartridge Cover, Small For PA7HE, Cartridge Cover, Medium, For PA7OVHE and PA7OVAGHE and PA7DEHE

CA113

Fabric Cover for straight breathing tubes (for use with PA031 and PA031L)

CA114

Fabric Cover for Y-shape breathing tubes (for use with PA034 and PA034L)

CA115

Fabric Cover for straight breathing tubes (for use with PA200 Series)

PA116

Dust Cap Cover

PA828

Hose Cover, Flame Resistant for PA036 or PA031L

PA761

Backpack for PA700 PAPR

PA728

4-Bay Charger Dock for PA700 PAPR

7003-H5

Refresher Wipes, with alcohol

80995

Cleaner/Sanitizer, 10 oz bottle (not available in Canada)

PA081

Air Flow Indicator

PA720

Standard Rechargeable lithium-ion battery for the PA700 PAPR

PA724

Single Charger w/Power Cord for PA720 rechargeable battery

*Coming Soon **High-Efficiency Particulate Air-Purifying, 99.97% minimum filter efficiency for all particulates.

26 I sps.honeywell.com I Respiratory Protection Catalogue

Respiratory Protection RESPIRATORY > CONSTANT FLOW SUPPLIED AIR RESPIRATOR (CF-SAR)

CF-SAR are practical solutions where concentrations of contaminants may be higher but not immediately dangerous to life and health, and where the cooling effect of a continuous flow of air is desirable. Honeywell offers a wide range of choices for both types of respirators in half-mask, full facepiece, and hood styles to suit almost any application. Our technologically engineered designs ensure a comfortable fit and reliability to keep workers protected throughout their work day. CF-SAR utilize an airline hose to supply air to the user. These respirators are a good choice when respirators will be worn for extended periods, best for locations that are extremely dusty or have high concentrations of contaminant requiring frequent change out of cartridges/filters. SUPPLIED AIR RESPIRATOR

CONSTANT FLOW SUPPLIED AIR RESPIRATOR (CF-SAR) Compressed air from outside the hazard area delivered to a coalescing filter for cleaning and then to the respirator waist belt for regulating to a constant flow, delivering cool clean air into the face piece.

AIRVISOR MV Compressed air from outside the hazard area is delivered to a coalescing filter for cleaning and then to the respirator waist belt for regulating to a constant flow, delivering cool clean air into the face piece. Air is also available for air tools.

4

1 Compressed air 2 Coalescing filter

1 Compressor 2 Coalescing filter

4

3 Regulator 4 Face piece 5 Air Tool

3 Regulator 4 Face piece

3

3

5

1

1

2

2

Respiratory Protection Catalogue I sps.honeywell.com I 27

Respiratory Protection

RESPIRATORY > CONTINUOUS FLOW SUPPLIED-AIR RESPIRATORS (CF-SAR)

SELECT FACEPIECE CONTINUOUS FLOW SUPPLIED-AIR RESPIRATORS (CF-SAR) REFERENCE CHART 1

NIOSH-Approved CF-SAR LOOSE–FITTING FACEPIECE

EN-Approved CF-SAR AIRVISOR

TIGHT–FITTING FACEPIECE

550030

54001

PA101

PA111

PA131/PA141

RU850001

RU65001

Airvisor 2 Loose - Fitting Facepiece with Breathing Tube and Air Diffuser

PA231E01

PA331

PA201E01

PA301

770030

76008A

2

Select a CF-SAR Assembly

CF1000

CF2007

Vortex Tube (optional)

Coupler Kit - Male Plug to connect on Breathing Tube - Female Coupler to connect on Airline Hose

3

Select Coupler Assy to connect Breathing Tube to Airline Hose

Female coupler to connect with male plug on Vortex Tube

4

Select Airline Hose

Coalescing filter

5

Select Male plug to connect Airline Hose to Air Source

Male Plug

> Filtration Panel

Air Source (supplied by third party)

> Air Source (supplied by third party)

28 I sps.honeywell.com I Respiratory Protection Catalogue

Made with FlippingBook - professional solution for displaying marketing and sales documents online