Honeywell- Impact Structural Fire Fighting
Authorised Distributor: Northrock Safety Equipment Pte Ltd
PROTECTIVE GARMENTS FOR STRUCTURAL FIRE FIGHTING
FEEL THE DIFFERENCE The Turnout gear is a suit designed to protect firefighters while doing firefighting and rescue operations. The Turnout gear is new series which is used to protect firefighters from the flame and heat that occur during firefighting operations. Turnout Gear is the most advanced range in the technical textile, which ensures to provide the solutions great comfort, performance and protection during the fire fighting applications. According to the (EU) 2016/425 PPE regulation firefighting suits have an EU Type Examination Certificate and carry the CE mark in its label. EN 469:2020 Protective clothing for firefighters - Produced in accordance with the standard "Performance rules for protective clothing used in firefighting".
Specifications
Outer Shell
Made from Inherent Flame Resistance fabric 93% Meta Aramid, 5% Para-Aramid, 2% Antistatic with 200 GSM (+/-5%) Flame Resistance non-woven Laminated with PTFE / PU membrane with -115 GSM (+/-5%) Aramid Non-woven quilted to Aramid- Viscose Woven fabric - 210 GSM (+/- 5%) 2" Wide Fire Retardant - Lime Silver Lime Reflective Trims » Single Strip at chest area.
Moisture Barrier
Thermal Barrier
Reflective Tape
» Single strips at bottom of jacket. » Double strips on sleeves of jacket. » Single strips on bottom of pants
Design And Features
1.
Our Fire Fighting Suit comes in Jacket & Trouser style which is made of inherent flame resistance fabric. The outer shell is flap conceals the zipper and has a Velcro for extra protection. For high visibility, FR fluorescent reflective tape is applied on chest round, Arms round of jacket. The entire pant is held in place by adjustable FR suspenders and FR Buckles. Throughout the garments manufacturing FR accessories and thread is used. Reinforced Fabric Stitched at Sleeves, Knee, and shoulder for better abrasion protection.
2. 3. 4. 5. 6.
Graphical Representation
Honeywell Offers A Versatile Line Of Products Designed To Meet The Different Applications And Requirements Of Firefighting Forces Across The World. • INDUST RIES AN D APP LIC A TION S
Honeywell First Responder High Risk (HFRP)
Thr oat Closu re T ab Extra protection in neck area
Reinforced Shoulders Longer durability in high abrasion area
Nametag FF identification
Flashlight Holder Holds flashlight in place
Reinforced Elbow Longer durability in high abrasion area
Sleeve Guard Prevents debris from entering sleeve
Knitted Cuffs with Thumb Loops Prevent sleeve retraction
Elastic and Adjustable Suspenders Comfortably hold pants in place
Vertical Reflective Trim on Legs Increased visibility
Premium Thermal Liner Enhanced comfort
Full-bellows pant pockets Extra capacity to hold needed equipment
Reinforced Knees Longer durability in high abrasion area
Cuff Tighteners Ensures position of sleeve and glove
Vertical Reflective Trim on Legs
Liner Pocket Additional and convenient storage
Suits Consists Of
COAT
FEATURES
CERTIFIED
• Curved collar for better fitting and looks. • Front closure with zip and snap button, durable compared to Velcro closure. • Knitted cuff, for better fitting. • Self-folding Placket, for neat finish and looks. • Bottom fold over for better look. • Inside clean finish
EN 469:2020 Fire Fighting Coat
INHFRCS INHFRCM INHFRCL INHFRCXL INHFRCXXL
PANT
FEATURES
CERTIFIED
• Clean finish Bid, concealed seams for good finish. • Suspender with buckles, for easy donning.
INHFRPS INHFRPM INHFRPL INHFRPXL INHFRPXXL
EN 469:2020 Fire Fighting Pant
• Inside clean finish, with concealed seams for improved finish. • Dark Color is less apparent to soiling and staining,maintaining good state for longer time. • Varying sizes available ranging from S to XXL. • Reinforced Fabric at Knee Area for abrasion protection
HOOD
FEATURES
CERTIFIED
INHFRHOOD
• Made of single ply premium, lightweight, inherent flame resistant (IFR) fabric • Durable material and colorfast • Lays flat on head to ensure comfort when wearing hard hat • Added stretch around eye area for comfort where you need it
EN 13911 Fire Fighting Balaclava Hood
GLOVES
FEATURES
CERTIFIED
INHFRG
• Made of single ply premium, lightweight, inherent flame resistant (IFR) fabric • Durable material and colorfast • Reflective tapes on Gloves for better visibility
EN 659 Fire Fighting Hand Gloves
FIRE FIGHTING SHOES HS 66-496
FEATURES
CERTIFIED
• Water resistant and flame retardant leather upper. • TECtuff® toe bumper to protect against scuffing.
AS/NZS 4821:2014 EN 15090:2012 Type 2 Structural Firefighting Footwear
• Lightweight, hi impact, non-metallic, wide profile Type 1 toe cap with a padded latex cushion liner to ensure toes not in contact with cap. • Fully lined with SYMPATEX® water proof liner & membrane. • Heavy duty red Nomex™ stitching. • COMFORTcushion® Impact Absorption System with PORON™ protects the heel and ball of the foot.
Sizing
We ar e r b ody d i m e ns i on range ( c m)
X
SIZE
X ( C h e st) 86-94 94-102 102-109 109-117 117-124
Y ( W a i st)
Z ( Hei ght) 164-170 168-174 172-178 176-182 180-186
S
79-97
Z
M
86-104 94-112 102-119 109-127
L
Y
X L
XX L
PRODUCT: COAT
inches (INHFRC)
Me asur e m e nt i n In c h e s ( C oat) SIZ E A
B
S
21 ½
23 ½
M
23
24
L
24 ½
24 ½
X L
26
25
XX L
27 ½
25 ½
PRODUCT: PANT
inches (INHFRP)
Me asur e m e nt i n In c h e s ( Bi b O v e rall) SIZ E C
D
S
24
29 ½ 29 ¾
M
25 ½
L
27
30
X L
28 ½
30 ¼ 30 ½
XX L
30
How To Measure
A B C D Chest: End to end at chest below 1" under arm Sleeve: From shoulder point to cuff end Waist: End to end at waist flare opened Inseam: From crotch to end of bottom
WARNING
• Flammable contaminants reduce the thermal performance of any flame resistance garment. • Wash garment to ensure that no greases, oily soils or other flammable contaminants are present when garment are worn. • The user is responsible for determining that this garment is appropriate for intended use and complies with all laws and regulatory standards.
WARRANTY INFORMATION • Prior to use of this garment a hazard assessment must be made by a trained safety professional. • It is necessary to assess hazards in the work environment and to match the appropriate personal protective equipment to hazards that may exist. • At a minimum, a complete and thorough hazard assessment must be conducted to properly identify the appropriate personal protective equipment to be used in a work environment. • Failure to read and follow all product warnings and instructions and to properly perform a hazard assessment may result in serious personal injury, illness or death. • Each new product is warranted to be free from defects in material and/or workmanship. • Honeywell’s responsibility is limited to, at its option, repairing or replacing any product for a period of SIX months after shipment in case of any material or workmanship defect. • All other warranties, express or implied, including the warranties of merchantability and fitness, are excluded.
CARE INSTRUCTIONS
• Inspect garment before each use for damage or contami- nates that impair the protective qualities of garment. • Clean thoroughly with detergent only, no softeners or starch should be used, refer to instruction for use for full care instructions. • The PPE should not be washed in temperature above 50°C. • Tumble dry at normal temperature . • Chlorine bleaches such as those containing sodium hypochlorite, oxygen bleaches, such as hydrogen peroxide as well as soaps (salts of fatty acids) should not be used to wash the PPE either separately or in detergent as they may affect the protective properties of the PPE.
The life of HFRP kit is dependent on its type, environmental conditions, contamination and degradation of the product.
STORAGE INFORMATION
Arc flash protective kit should be stored in their original packaging, kept in a controlled stock area, not subject to rapid changes in temperature, humidity levels, exposure to direct UV radiation/ sun light.
Certifications
Category III CAT. III
X2 Y2 Z2
0598
EN 469: 2020
EN 659:2003 +A1:2008 EN13911:2017
For more information on Honeywell arc flash protection offering visit: For more information on Honeywell arc flash protection offering visit: website - https://www.honeywell.com/in/en/impactbyhoneywell or Local Honeywell representative or write us at impact.sps@honeywell.com
Industrial Automation Honeywell International India Pvt Ltd 1120-21, 11th Floor, Tower A, DLF Tower, Jasola, Jasola District Centre, New Delhi - 110 025, India Email : impac t .sps@hone ywell .com
HFRP_TDS_Rev001 © 2024 Honeywell International Inc.