VARMEX FIRE JERSEY Product Catalogue
VARMEX® V420 FIRE Jersey
SPECIFICATIONS
Structure
Rib Knit
Yarn Blend 56% OPAN /28% Modacrylic / 15% Para-aramid / 1% Anti-static
Weight (+/-5%)
420 gsm
Width (+/- 1%)
150 cm
Cleansing Pretreatment: None. PPE DIRECTORY: Regulation (EU) 2016/425
Colours
Black
EN ISO 11612:2010 A1,A2,B1,C1,F1 EN ISO 1149-3:2004 EN 13911: 2017 EN ISO 14116:2008 3/3A/60
Standards
5 x 60 o C washes 3A & F tumble drying
Pre-treatment
ISO 6330 : 2012
5 Wash / Dry Cycles
Warp -4.5% Weft -1.5%
Knit: <
+ 5%
Dimensional change
EN ISO 5077: 2008
PASS
EN 11612 > 200kPa
Bursting Resistance
EN ISO 13938-2:2000
520kPa
PASS
Warp Weft @180 o C -0.4% -2.0% @260 o C -0.5% -0.7%
Heat Resistance
EN ISO 17493:2000
Shall not ignite or melt or shrink >5%
PASS
No flaming to edge, hole, molten or flaming debris Mean after-flame < 2s Mean afterglow < 2s No flaming to edge, hole, molten or flaming debris Mean after-flame < 2s Mean afterglow < 2s
Limited flame spread - Face ignition (A1)
EN ISO 15025:2015 Procedure A
PASS
A1
Limited flame spread - Edge ignition (A2)
EN ISO 15025:2015 Procedure B (folded edge)
PASS
A2
HTI 24 > 4.0s >10.0s
HTI 12 5.7s HTI 24 8.9s HTI 24 -HTI 12 3.2s 8.9s RHTI 24 16.4s RHTI 24 -RHTI 12 7.5s RHTI 12
Level B1 B2
ISO 9151: 1995 80k/Wm 2 EN367:1992
Convective heat (B)
B1
RHTI 24 > 7.0s > 20.0s t t > 5.0s > 10.0s
Level C1 C2
Radian heat ( C)
ISO 6942: 2002 Method B at 20kW/m 2
C1
Level F1 F2
Contact heat (F)
ISO 12127: 2007 @ 250 o C EN 1149 -3:2004
9.6s
F1
Charge decay
t 50 = Decay half time S = Shielding t 50 < 4s or S >0.2 Arc Rating (ATPV) HAF
t 50
13.11s 0.36
PASS
S
33.0 cal/cm 2 89.6%
Electric Arc
IEC 61482-1-1:2009 EN 614822-1-1 Method A
PASS
pH Value
ISO 3071:2005
NA
pH = 4.6
2
+(45) 55 44 66 44
www.varmex.eu
varmex@d-s.dk
Made with FlippingBook - professional solution for displaying marketing and sales documents online