VARMEX ALU Product Catalogue
VARMEX® V54 Non-flammable
SUMMARY OF RESULTS
Performance Standard:
EN ISO 11611: 2015
a) b)
Clause 6.6 Dimensional Change
Clause 6.7.2 Flame spread – Face ignition (A1)
Cleansing Pre-treatment:
Prior to Clause 6.6, five wash/dry cycles according to ISO 6330: 2012 Procedure 4N (40°C) with tumble drying (Procedure F) (max. 60°C outlet temperature). Clause 6.7.2 was performed in the “as received” condition only.
PROPERTY
TEST METHOD ISO 5077: 2007
EN ISO 11611 REQUIREMENTS Knitted fabrics: Class 1: ≤ ± 5% Class 2: ≤ ± 5%
RESULTS OBTAINED PASS/FAIL OR LEVEL
6.6 Dimensional change
Warp Weft -3.5% -3.6%
PASS
6.7.2 Limited Flame spread – Face ignition (code letter A1)
ISO 15025: 2016 Procedure A
Class 1 and Class 2: No flaming to edge No hole formation No flaming or molten debris Afterglow time ≤ 2s Afterflame time ≤ 2s
No flaming to edge No hole formation No flaming or molten debris
PASS A1 Class 1 & 2
No afterglow No afterflame
An estimation of uncertainty of measurement has been taken into account when making a judgement to any pass/fail criteria. Refer to Appendix A for further information.
1
+(45) 55 44 66 44
www.varmex.eu
varmex@d-s.dk
Made with FlippingBook Annual report maker