Rothoblaas Catalogue 2019
TECHNICAL ASPECTS
INSTALLATION
INSTALLATION GEOMETRY ON CONCRETE - THREADED RODS (TYPE INA or MGS)
s
c
h
min
c
s
d
[mm]
M8 M10 M12 M16 M20 M24 M27 M30
d 0
[mm] [mm] [mm] [mm] [Nm]
10 60
12 60
14 70
18 80
22 90
26 96
30
35
h ef,min h ef,max
108
120
160 200 240 320 400 480 540 600
d f
9
12 20
14 40
18 80
22
26
30
33
T inst
10
120 160 180 200
M8 M10 M12 M16 M20 M24 M27 M30
s min c min h min
Minimum spacing
[mm] [mm] [mm]
max (h ef max (h ef
/ 2; 5d) / 2; 5d)
Minimum edge distance
Minimum thickness of concrete support
h ef
+ 30 ≥ 100 mm
h ef
+ 2 d 0
For spacing and distances smaller than the critical ones, strength values have to be reduced depending on the installation parameters.
T
inst
t
d
fix
f
d = anchor diameter d 0 = hole diameter in the concrete support h ef = effective anchor depth d f = maximum hole diameter in the element to be fastened
T inst = tightening torque L = anchor length t fix = maximum fastening thickness h 1 = minimum hole depth
L
h
h
ef
h
1
min
d d
0
INSTALLATION TIME AND TEMPERATURE
curing time before loading
support temperature
workability time
dry support
wet support
+ 5 ÷ + 9 °C
120 min 45 min 25 min
50 h 30 h 18 h 10 h
100 h
+ 10 ÷ + 14 °C + 15 ÷ + 19 °C + 20 ÷ + 29 °C + 30 ÷ + 39 °C
60 h 36 h 20 h 12 h
12 min 6 min 5 min
6 h 4 h
+ 40 °C
8 h
Cartridge storage temperature + 5 ÷ + 25 °C
COMPLEMENTARY PRODUCTS | EPO-FIX PLUS | 211
Made with FlippingBook flipbook maker