Rothoblaas Catalogue 2019
TECHNICAL ASPECTS
STATIC VALUES - WASHERS PULL-THROUGH RESISTANCE
CHARACTERISTIC VALUES
Ø [mm]
standard
Ø int [mm] Ø ext [mm]
s [mm]
N ax,k [kN]
1,84 5,02 6,58
DIN 125 A DIN 9021 DIN 440 R DIN 1052 DIN 125 A DIN 9021 DIN 440 R DIN 1052 DIN 125 A DIN 9021 DIN 440 R DIN 1052
10,5 10,5
20,0 30,0 34,0 24,0 37,0 44,0 58,0 30,0 50,0 56,0 68,0 -
2,0 2,5 3,0 2,5 3,0 4,0 6,0 3,0 3,0 5,0 6,0 -
s
M10
11
-
-
2,59 7,63
13,0 13,0 13,5 14,0 17,0 17,0 17,5 18,0
Ø
int
M12
Ø
11,16 20,15
ext
3,89
N
14,07 18,00 27,36
ax
M16
CRITICALITY: WASHER HEAD PULL-THROUGH INTO TIMBER
N > N
ax,Max
N
N
ax
ax
NOTES:
- Characteristic values according to EN 1995:2008. - Design values can be obtained from characteristic values as follows:
The coefficients γ m and k mod should be taken according to the current regulations used for the calculation. - For the calculation process a timber density ρ k = 380 kg/m 3 has been considered. - The pull-through resistance of a washer is proportional to its contact surface with the timber element.
COMPLEMENTARY PRODUCTS | METRICS | 193
Made with FlippingBook flipbook maker