DO YOU KNOW 6

WHAT IS EN 342 ?

Moving Wearer

Standing Wearer

Level of Performance

Wearer moving activity

Level of Performance

Example:

Light, 115 W/m 2 Medium, 170 W/m 2 8 h 1 h 8 h 1 h

Wearer standing activity, 75W/m 2

Insulation, I cle

S585 WINTER COVERALL (page 171) Has an EN342 rating of 0.503m 2 . K/W

[m 2 . K/W]

Insulation, I cle

8 Hours 1 Hour

[m 2 . K/W]

0,310 0,390 0,470 0,540 0,620

-1 0 -8 0

0,310 0,390 0,470 0,540 0,620

11 0

-2 0

-15 0 -25 0

-19 0 -28 0 -38 0 -49 0 -60 0

-32 0 -45 0 -58 0 -70 0 -83 0

7 0 3 0

-10 0 -17 0 -25 0 -32 0

-15 0 -35 0 -22 0 -44 0 -29 0 -54 0

-3 0 -7 0

CS12

This standard speci es requirements and test methods for performance of two piece suits, coveralls or single garments for protection against cold environments (characterised by a combination of humidity , wind and at air temperature lower than -5 °C).

Using S585 thermal rating as an example, a person wearing S585 standing still, can withstand 17 0 C for 1 HOUR and 3 0 C for 8 HOURS .

A person wearing S585 performing light activity can withstand 35 0 C for 1 HOUR and 15 0 C for 8 HOURS A person wearing S585 performing mediumactivity can withstand 58 0 C for 1 HOUR and 38 0 C for 8 HOURS

The following parameters are used: A =Thermal insulation B = Air permeability (Class 1, 2 or 3) C = Resistance to water penetration (optional) (Class 1 or 2) EN 342

The following styles are certi ed to EN 342: FR53,FR58, FR59, RT34, S485, S460, RT30, S466, S467, R460, R463, S463, S434, S433, S482, S585, CS12, CS10, CS11, S816 EN 342

Made with FlippingBook Annual report