Northrock PPE Catalogue

Portwest's technical flame resistant products have been tested to the highest international safety standards including ISO 13506, the manikin flame engulfment test. UNDERSTANDING MANIKIN TEST RESULTS Following flame exposure, a body map is created, which uses colour coding to indicate the burn injury prediction results FLAME ENGULFMENT MANIKIN TEST

FR50 + FF50

BURN INJURY PREDICTION 0.0%

Pain (12.3%) 1st° Burn (0.9%) 2nd° Burn (0.0%) 3rd° Burn (0.0%)

FR28

TABLE OF RESULTS

BURN INJURY PREDICTION 1.8%

1st° Burn

2nd° Burn

3rd° Burn

Burn Injury Prediction

FR50/FF50

0.0%

0.9%

0.0%

0.0%

Pain (19.3%) 1st° Burn (0.0%) 2nd° Burn (1.8%) 3rd° Burn (0.0%)

FR60

0.9%

2.6%

0.9%

0.0%

FR28

1.8%

0.0%

1.8%

0.0%

FR21

19.0%

6.0%

19.0%

0.0%

AF53/AF73

8.8%

3.5%

7.0%

1.8%

AF22

6.2%

0.0%

5.3%

0.9%

FR55/FR56

3.0%

2.0%

3.0%

0.0%

FR55/FR57

0.0%

BEST IN CLASS BURN INJURY PREDICTION RESULTS

1.0%

0.0%

0.0%

FR25/FR26

3.0%

2.0%

3.0%

0.0%

FR25/FR27

0.0%

1.0%

0.0%

0.0%

FR61/FR62

0.0%

0.0%

0.0%

0.0%

Continuous investment in product testing is central to our product development approach as it offers reliable validation of our ongoing commitment to wearer comfort and safety.

FR61/FR63

0.0%

1.0%

0.0%

0.0%

BIZ1

1.8%

0.9%

1.8%

0.0%

BIZ2/BZ30

5.3%

0.0%

4.4%

0.9%

|235