H-BASE DAVIT ARM AFT751011
AFT751030/AFT751031-Wall Mounted Davit Installation
Ÿ Ÿ Ÿ Insert the column in the wall Mounted Base AFT7500BW Lock the column with the base with locking pin. Repeat Step 9-14 to install brackets for winch and Rescue Retrieval SRL (Type 3)
AFT7500BW
Locking Pins
0 360
NOTE: The receiving structure must be able to withstand stresses equivalent to 22.1 MPa or 22.1N/mm2. The fasteners/structural anchors must be strong enough to handle this strain. They must be stainless steel/High tensile, sizeM16. Ÿ Thickness of concrete block should be minimum 9"(228.6mm) Ÿ Drill hole should have aminimum clearance of 11"(279.4mm) fromall the available edges Ÿ All receiving Structure should be verified by a qualified structural Engineer. Ÿ Can be installed on cantilever of concrete beam by sandwiching two plates on beam& concrete structure should be verified by a qualified structural Engineer. Ÿ SuitableM16 fasteners should be used for fixing the brackets to the structure. Ÿ For dismantling the product, go through the described steps in reverse order. Ÿ Base Installation must be approved to local regulations by a qualified engineer. Ÿ Refer to Fastener Manufacturer to ensure the correct fasteners are used. Ÿ If the Base material does not meet the minimum requires to install, then reinforcement is required. Refer to a qualified engineer.
Rotation Degrees
300.0 240.0
Ø22.0(4holes)
Ø102.0
.
5
300.0
240.0
293
AFT7500BF
Ø22.0(4holes)
300.0
240.0
221.2
Ø102.0
300.0 240.0
AFT7500BW
8