ECOSAFE Catalogue

Authorised Distributor: Northrock Safety Equipment Pte Ltd

FLAMMABLE CABINETS

www.ecosafesa.com

CORROSIVE CABINETS

TOXIC CABINETS AND MULTIRISK

PESTICIDE CABINETS

DUCTLESS FUME HOODS FILTERING CABINETS VENTILATION

SHELVINGS CONTAINMENT CANS

YOUR ECOSAFE RESELLER :

ANTI-FIRE EQUIPMENTS FILE CABINETS

SHOWERS AND FIRST-AID EQUIPMENTS

ECOSAFE EUROPE Tel. : +41 (0)21 694 10 04 Fax : +41 (0)21 694 10 00

ECOSAFE ASIA Tel. : +852 3919 5812 Room TA 12, 6th floor Woon Lee Commercial Building N° 7-9 Austin Avenue Tsim Sha Tsui - Hong Kong S.A.R.

Chemin des Champs Courbes 15 Zone Industrielle de Vallaire Est 1024 - Ecublens - Switzerland

Sept. 2019 Edition

Flammable cabinets

ECOSAFE is the manufacturer of safety products that offers the widest range of the world in this field, from storage (with our safety storage cabinets) to manipulation of chemicals (with our ductless fume hoods). Specialized for more than 30 years in chemicals manipulation and storage for industries, laboratories and universities, ECOSAFE is happy to present our complete new catalogue offering our whole product range.

For many years, we have tried to improve our quality and offer , and to follow the direct line of development by respecting :

cabinets

Corrosive

• Manufacture and certification with the strictest existing norms on the market, • Control and price cutting that allow to propose competitive price lists, • A know-how that maintain our production in Western Europe, • A dedicated office and team based in Hong Kong for the Asia Pacific region.

All the products presented in this catalogue are the result of our principles.

The ECOSAFE products conform to the strictest existing norms in our field :

• EN 14470-1 for our safety cabinets for flammables, • FM & OSHA for the cabinets for industries, • NF X 15-211 - may 2009 for our ductless fume hood, • EN 15154-1 & EN 15154-2 for our safety showers and eye-washers.

and multirisk

Toxic cabinets

ECOSAFE , stands also for :

08/2019

• An important and permanent technical and sales support for our partners with a team that is able to answer to all your questions and needs, • A logistic solution to insure a rapid and safe delivery, • A wide range of partners all over the world that help us to grow ECOSAFE recognition and showcase the quality of our products, • A high visibility thanks to the participation in the biggest exhibitions in the world , by ourselves or in collaboration with our partners, • International scope and mindset.

Pesticide range

ECOSAFE , in figures, it is :

cabinets - Ventilation

• 220 000 safety cabinets and ductless fume hoods sold all over the world, • 2500m 2 of manufacture space for improving quality and production, • 3000 m 2 of storage for a rapid delivery all over the world, • More than 900 references of products in order to answer all the needs of our customers.

Fume hoods, filtering

Containment and Cans

Jean-Michel THIEULIN General Sales Director

Stefano DI LEO Sales Manager

Laurent STIEGER Asia Sales Director

Victor ZHANG Greater China Manager

Kenny Fu Ka Hong Area Sales Manager

Anti-fire equipments and File cabinets

Showers and First- equipments

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

ECOSAFE EUROPE Tel. : +41 (0)21 694 10 04 Fax : +41 (0)21 694 10 00

ECOSAFE ASIA Tel. : +852 3919 5812 Room TA 12, 6th floor Woon Lee Commercial Building N° 7-9 Austin Avenue Tsim Sha Tsui - Hong Kong S.A.R.

Chemin des Champs Courbes 15 Zone Industrielle de Vallaire Est 1024 - Ecublens - Switzerland

A question ? An advice ?

• Website : www.ecosafesa.com • E-mail : sales@ecosafesa.com

SELECTION GUIDE

You store chemical products

We propose you Cabinets type 105 min Cabinets type 60 min Cabinets type 30 min

Range

You are in compliance with

Pages

790+ - 790+T

12, 14

EN 14470-1 FM 6050

Safety cabinets with fire resistance

760+

22

3030 - 3030T 3030PV - 7030

24 to 27 - 30 to 31

Flammable cabinets

FM cabinets

2 1

FM 6050 – NFPA – OSHA

38 37 40 47 98

Safety cabinets with extinguisher

-

Flammables

Safety cabinets

Safety storage cabinets

3/5

NF EN ISO 1182

Secure cabinets Safety shelvings

14.E

- - -

Safety shelvings Containment tanks

R

BR

95 - 97

Containment tanks

G S

EPA – UFC

96

Stainless steel cans

FM – UL

102 100

Safety cans

Steel cans FM cabinets

J 4

FM – NFPA – OSHA FM – NFPA – OSHA

Safety cabinets built in steel Hight-corrosive products safety cabinets

45

Corrosives

cabinets

Corrosive

Corrosion resistant cabinets

8.A & 8.B

46 - 47

Cabinets type 30 min

3030.M

EN 14470-1

48 98

Safety shelvings

Safety shelvings

R

- -

BR

95 - 97

Containment tanks

Containment tanks

G

EPA – UFC

96

Safety cans

HPDE cans

J

FM

100

Ventilation cabinets

13

-

57 78 80 82 98 96 60 52 54 55 51 81 82 84 86 64 63 64 98 98 58

Toxics / noxious

Safety cabinets

Filtering ventilation safety cabinets Filtering ventilation secure cabinets

12.X 14.X

NF X 15-211*

Filtering ventilation safety cabinets type 30 minutes

3030.X

NF X 15-211* - EN 14470-1

and multirisk

Toxic cabinets

Safety shelvings

R

- -

Safety shelvings

BR

95 - 97

Containment tanks

Containment tanks

G

EPA – UFC

Different chemical families (flammables, corrosives, toxics, noxious...)

Under-bench cabinets

6

Multirisk and modulable secure cabinets

14

Secure cabinets

14.L 14.T 14.E

-

07/2019

Secure cabinets with drawers

Secure cabinets

Pesticide range

Multirisk cabinets type 105 min Multirisk cabinets type 90, 60 min Multirisk cabinets type 30 min Filtering ventilation safety cabinets

790+M

8 - 16 - 59

Safety cabinets

11+B

EN 14470-1

3030.M

28 - 56

12

Filtering ventilation safety cabinets Labopur Filtering ventilation secure cabinets Labopur Filtering ventilation safety cabinets type 30 minutes

12.X 14.X

NF X 15-211*

3030.X

NF X 15-211* - EN 14470-1

Safety cabinets Secure cabinets

16.E 16.L 16.K

Pesticides

Safety cabinets

-

Ready to build secure cabinets

HPDE safety shelvings Steel safety shelvings

R R

Safety shelvings

cabinets - Ventilation

Fume hoods, filtering

EPA – UFC

BR

95 - 97

Containment tanks

Containment tanks

G

96

Lithium-ion batteries

Safety cabinets

Antifire safety cabinets

790+LI

20

Gas cylinders

Safety cabinets

Antifire safety cabinets

7630BG

EN 14470-2

32

Fire resistant filing/document cabinets

NT Fire 017

108 to 110

AD73-AD76-AD79

Containment and Cans

Filing/ document

Safe for documents

Safe for documents

AD3 & AD4

NF EN ISO 1182

106,107

Fire resistant safe for documents Indivudual lockers for smartphones

AD30

113 110

Smartphones

Secure cabinets with individual lockers

21

You need to collect your wastes Flammables

Cabinets type 105 min for recovery of waste Cabinets type 30 min for recovery of waste

7.90ARD 3030.ARD

EN 14470-1

15 26

Safety cabinets

EN 14470-1 - FM 6050

You use chemical products Flammables, corrosives, toxics, noxious...

Labopur ductless fume hoods

H H H H H V V H V

66 to 74 - 80

Ductless fume hoods

NF X 15-211 – Classe 2

77 78 79 76

PMSF – Ductless fume hood and storage cabinets with recirculating air

Laminar flow clean benches Biological safety cabinets Fume hoods with external connection

Laminar flow clean benches Biological safety cabinets

EN 12469 - ISO 14644-1 classe 3

Anti-fire equipments and File cabinets

Fume hoods with external connection

You would like to vent your cabinet

Ventilation boxes

-

90 91

Without active charcoal filter

ATEX ventilation boxes Recycling air box Labopur

ATEX

Ventilation

NF X 15-211*

88 - 89

With active charcoal filter

Filtration boxes

-

90

You need equipments Fire Protection

Safety waste bins

Safety waste bins

P & J

TNO – IBBC – NVBB – FM

107 - 108

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Fire blankets

Fire blankets

A C

EN 1869-1997

104 109

Showers and First- aid equipments

Safety ashtrays

Safety ashtrays Combination units

-

DL DL DL DL DL 19

EN 15154-1, EN 15154-2

120 to 122

First-aid

Showers connected to water network Eye-washers connected to water network

EN 15154-1 EN 15154-2

126

Safety combination units, showers and eye-washers

124 - 125 - 127

Portable shower stations Autonomous eye-washers

123 129 130

-

Medicine cabinets

Medicine cabinets

*Active charcoal filters adsorbtion’s capacity and filtration system are tested and certified NF X 15-211 - may 2009.

ACTIVE CHARCOAL FILTERS SELECTION GUIDE

P/N from 2011

Weight (kg)

P/N before 2011

For

Kind of filter

Filter for vapors

Flammable cabinets

Filtration boxes and Filtering ventilation cabinets

Organic

CDFORG 3

CDF-F20

Corrosive

CDF-F35

Range V - Boxes : CDF-A, CDF-P, CVAT, CMAT, CTAT

CDFCORG 3

Polyvalent (1)

CDF-F15

cabinets

- -

Corrosive

CDFFOR 3

Formaldehyde

H 150 x Ø 150 (mm)

CDFAMM 3

Ammonia

Organic

ORG50

8

ORG50

Polyvalent (1)

CORG51

9

CORG51

Range H - Boxes : H50

- -

FOR50

8

Formaldehyde

and multirisk

H 70 x W 390 x D 390 (mm)

Toxic cabinets

AMM50

8

Ammonia

CDFORG 4

CDF-F20

Organic

CDF-F35

Corrosive

04/2017

CDFCORG 4

Range 12 Cabinets: AF10

Pesticide range

CDF-F15

Polyvalent (1)

- -

CDFFOR 4

Formaldehyde

H 150 x Ø 150 (mm)

CDFAMM 4

Ammonia

ORG50

8

CFR720

Organic

CFR735

Corrosive

Range 12 - Cabinets: AF1, AF2 (before February 2002)

CORG51

9

CFR - CFR70 - CFR715

Polyvalent (1)

cabinets - Ventilation

Fume hoods, filtering

- -

FOR50

8

Formaldehyde

H 70 x W 390 x D 390 (mm)

AMM50

8

Ammonia

Range 12 - Cabinets: AF1, AF2 (before February 2002)

Polyvalent (1)

FCR

1

FCR

Containment and Cans

H 20 x W 390 x D 390 (mm)

ORGFC 10

FC20

Organic

Range 12 - Cabinets: AF1, AF2, AF2-2, AF4-2, AF4-3, AF4-4 (before July 2008) H40

FC35

Corrosive

CORGFC 10

FC15

Polyvalent (1)

- -

FORFC 10

Formaldehyde

Anti-fire quipments and File cabinets

H 200 x W 100 x D 400 (mm)

AMMFC 10

Ammonia

ORG300

16

FC20

Organic

Range 12 - Cabinets: AF1, AF2, AF2-2, AF4-2, AF4-3, AF4-4 (before July 2008)

FC35

Corrosive

CORG301

15

FC15

Polyvalent (1)

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid quipments

- -

FOR300

16

Formaldehyde

H 70 x W 730 x D 380 (mm)

AMM300

16

Ammonia

(1) organic + corrosive. CORG polyvalent active charcoal filters can adsorb the most common chemical products used: organic and inorganic acids, organic compounds or solvents.

2

ACTIVE CHARCOAL FILTERS SELECTION GUIDE

ORG50 CORG51 FOR50 AMM50 P/N from 2011 ORG200 CORG201 FOR200 AMM200 ORG300 ORG400 ORG1300 ORG2300 CORG301 CORG401 CORG1301 CORG2301 FOR300 FOR400 FOR1300 FOR2300 AMM300 AMM400 AMM1300 AMM2300 ORG500 ORG1500 ORG2500 ORG3500 CORG501 CORG1501 CORG2501 CORG3501 FOR500 FOR1500 FOR2500 FOR3500 AMM500 AMM1500 AMM2500 AMM3500 ORG203 CORG203

Weight (kg)

P/N before 2011

Models

For

Kind of filter

Filter for vapors

Fume Hoods

Flammable cabinets

8 9 8 8

- - - -

Organic

Range H Fume hoods : H60 and H70 Range H Fume hoods :

Polyvalent (1) Formaldehyde Ammonia Organic Corrosive Polyvalent (1) Formaldehyde

H 70 x W 390 x D 390 (mm)

11

ORG200 COR200 CORG201

11,5

H200, H201 H210, H211 PMSF200 H06, H09, H12, H15

12 12

- -

cabinets

Corrosive

Ammonia

H 70 x W 545 x D 380 (mm)

ORG300 ORG400 ORG1300 ORG2300 COR300 COR400 COR1300 COR2300 CORG301 CORG401 CORG1301 CORG2301

16

Organic

Corrosive

Range H Fume hoods : H300, H301, H310, H311, H400, H401, H410, H411, H1300, H1301, H1310, H1311, H2300, H2301, H2310, H2311, PMSF400, PMSF1300, PMSF2300

and multirisk

Toxic cabinets

15

Polyvalent (1)

H 70 x W 730 x D 380 (mm)

08/2019

- - - - - - - -

16

Formaldehyde

Pesticide range

16

Ammonia

ORG500 ORG1500 ORG2500 ORG3500 COR500 COR1500 COR2500 COR3500 CORG501 CORG1501 CORG2501 CORG3501

22

Organic

Corrosive

Range H Fume hoods : H500, H501, H510, H511, H1500, H1501, H1510, H1511, H2500, H2501, H2510, H2511, H3500, H3501, H3510, H3511, PMSF1500

cabinets - Ventilation

Fume hoods, filtering

23

Polyvalent (1)

- - - - - - - -

24

Formaldehyde

Containment and Cans

(2x) H 70 x W 545 x D 380 (mm)

24

Ammonia

13 13 13 13 15

Compatible MF3-AS ORG203 Compatible MF3-BE CORG203

Organic Corrosive

- 806 NU - Filtair 623/633 MF - Filtair 936/936-1 MF - Filtair XL 1046/1346/1646 MF - Filtair XL 9156 MF - Midcap 633 MF - Filtair 814/824/834 HEPA/ Carbon - Filtair XL 1044/1344 MF - Filtair XL 8104/8124 MF - Midcap 804 MF - Store AVP 804 MF - Store AVP 804 Midcap MF - Store AVPD 804 MF - Store AVPD 804 Midcap MF - Store AVPS 804 MF - Store AVPS Midcap 804 MF - Store AVPSD 804 MF - Store AVPSD Midcap 804 MF - Store AVVE 804 MF Don’t forget,weareable toprovide specialisedfilters for specificapplications for fumehoods,filteringventilation cabinets,filtrationboxes... in standardma- nufacturingand in specificmanufacturing, contact-us formore information.

Polyvalent (1) Formaldehyde

FOR203 AMM203 ORG303

Compatible MF3-F Compatible MF3-K

- -

H 100 x L 565 x P 405 (mm)

Ammonia Organic Corrosive

Anti-fire equipments and File cabinets

Compatible MF4-AS ORG303

16

CORG303

Compatible MF4-BE CORG303

Polyvalent (1) Formaldehyde

16

FOR303

Compatible MF4-F

-

AMM303

16

Compatible MF4-K

-

Ammonia

H 100 x L 755 x P 405 (mm)

Showers and

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

first-aid equipments

Polyvalent Organic Polyvalent Organic

CORG53 ORG53 CORG13 ORG13

7 6 4 3

Compatible F2BE Compatible F2AS Compatible F1BE Compatible F1AS

(1)

H 404 x L 380 x P 50 (mm)

(1)

H 404 x L 191 x P 50 (mm)

(1) organic + corrosive. CORG polyvalent active charcoal filters can adsorb the most common chemical products used : organic and inorganic acids, organic compounds or solvents. We can offer filters for specific applications for all models of fume hoods, air recirculating fume cupboards, safety cabinets... in manufacturing stand or special manufacturing.

3

UNDER-BENCH CABINETS BY CHEMICALS STORED

For flammable products with fire resistance

Flammable cabinets

cabinets

Corrosive

Range 790+ - Model 792+E EN 14470-1 - 105 minutes (Also available in 60 minutes)

Range 790+ - Model 791+E EN 14470-1 - 105 minutes (Also available in 60 minutes)

Range 3030 - Model 3032E EN 14470-1 - 30 minutes

and multirisk

Toxic cabinets

Range 3030 - Model 3031E EN 14470-1 - 30 minutes

Range 790+ - Model 792T+ EN 14470-1 - 90 minutes (Also available in 30 minutes, model 7032T)

Range 7030-Model 7031T EN 14470-1 - 30 minutes (Also available in 90 minutes, model 791T)

07/2019

Pesticide range

For flammable products

cabinets - Ventilation

Fume hoods, filtering

Range 2 -Model SB18 FM - 10 minutes

Range 2 -Model SB04 FM - 10 minutes

Range 6 - Model SV30

Range 6 - Model SV50

For high-corrosive pro ducts

For corrosive products

Containment and Cans

Anti-fire quipments and File cabinets

Range 8.A - Models APC31 and APC61 Range 8.B - Models APC32 and APC62

Range 6 - Model AC30

Range 4 - Model B18S

For toxic and noxious products

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid quipments

Range 3 - Model SV50

Range 14 - Model ASPD

Rangev 14 - Model ASP Range 6 - Model TO30

4

UNDER-BENCH CABINETS BY CHEMICALS STORED Multirisk (flammables, corrosives,toxics,noxious...)

Flammable cabinets

cabinets

Corrosive

Range 3030M - Model 3032M11

Range 14 - Model AB56

Range 790+M - Model 792+M11

and multirisk

Toxic cabinets

07/2019

Pesticide range

Range 6 - Model AS60

Range 6 - Model BT60

cabinets - Ventilation

Fume hoods, filtering

Range 6 - Model BS60

Range 6 - Model AB60

Containment and Cans

Anti-fire equipments and File cabinets

Range 6 - Model ABS90

Range 6 - Model ST60

Showers and

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

first-aid equipments

Range 6 - Model ABST120

5

REGULATIONS

Flammable cabinets

FM(FACTORY MUTUAL) : Offers worldwide industrial and commercial product certification and testing services throught its business unit FM Approvals. Recognized and respected across the globe, FM approvals certification assures customers that a product has been objectively tested and conforms to the hightest national standards. The FM certification requires a fire-resistance of 10 minutes for Safety cabinets, according to the heating curve NFPA 251-1969. EUROPEAN NORM EN 14470-1: It is applicable for storage of flammable and highly flammable chemicals in a laboratory. The flammables used in laboratories must be stored in one or several safety cabinets which are fire resistant 15 (minimum required),30,60 or 90 minutes. EUROPEAN NORM EN 14470-2: It is applicable for storage of gas cylinders in laboratories. The gas cylinders used in laboratories must be stored in one or several safety cabinets which are fire resistant 15 (minimum required),30,60 or 90 minutes. NF X 15-211 - MAI 2009 NORM: The standard indicate on the ventilation and filtration efficiency, as well as the Containment efficiency for the recirculatory fume hood designed for chemicals use in laboratories. EUROPEAN NORM EN 1869-1997: This norm indicates that a fire blankets must be able to resist to a heat 900°C done by a fresh fuel oil (such as edible soya bean oil or rapaseed oil). The electric resistance must not be below 1 Ohm.

cabinets

Corrosive

EN 14470-1

and multirisk

Toxic cabinets

EN 14470-2

NF X 15-211

08/2015

Pesticide range

EN 1869-1997

ISO 1182 EN 15154-1 / 2 NT Fire 017

EUROPEAN NORM EN ISO 1182: Indicates the test for the non flammables buiding materials (Thermic insulation).

cabinets - Ventilation

Fume hoods, filtering

EUROPEAN NORM EN 15154-1 AND EN 15154-2: This regulation concerns first aid equipment and especially body showers and eye-washers, connected to water network.

NT FIRE 017: Swedish standard in as per the market of cabinets to store documents and IT furnitures. 3 sorts of fire resistance : 30,60, and 90 minutes. GHS - Globally Harmonized System of Classification and Labelling of Chemicals (only concers the safety container of the chemical itself, do not apply to safety storage cabinets : is an internationally agreed-upon system, created by the United Nations. It supersedes the relevant system of the European Union, which has implemented the United Nations’GHS into EU law as the CLP Regulation and United States Occupational Safety and Health Administration standards. Not to be confused with ISO 7010 and ISO 3864. I SO 7010/ISO 3864 (Relates to the labelling affixed to the safety cabinets) : The ISO 7010 prescribes the safety signs to be used in the context of accident prevention, fire fighting and information on the risks of health’s damages. The shape and color of each safety signs and the design of the graphic symbols conform to ISO 3864.

Containment and Cans

GHS

ISO 7010 / 3864

Anti-fire quipments and File cabinets

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid quipments

6

STICKER REGULATIONS AND CHEMICALS INCOMPATIBILITIES

Flammable cabinets

Chemicals incompatibilities

you must store them in a safety cabinet/compartment for

Xn

Xi

The sticker on your cans is

+ -

-

O + O O

Flammables

cabinets

Corrosive

-

O -

Corrosives

Toxics

-

-

+ + O

C.M.R products

and multirisk

Toxic cabinets

Environmental hazards

Xn

O O + + + + O O + + O Do not store, handle or waste together except if particular conditions are applied Xi

07/2019

Healthcare hazards/Irritants - Noxious

Pesticide range

+ Compatible products - Non compatible products

You need a clear and understandable information to install our cabinets, fume hoods or filtration boxes? Refer to our tutorials in video and much more on... http://www.ecosafesa.com/fr/catalogue/videos

cabinets - Ventilation

Fume hoods, filtering

Containment and Cans

Anti-fire equipments and File cabinets

Showers and

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

first-aid equipments

7

RANGE 790+M EN 14470-1 EN 1363-1

Multirisks safety cabinets with ventilation and filtration in as per the highest regulation EN 14470-1 : Fire resistance 30 minutes and NFX15-211 (1) : Filtration of the fumes SECUMAX90SAFETYCABINET

Flammable cabinets

cabinets

NF X 15-211 Class 2 - May 2009

Corrosive

EN 14470-1 Type 30 or 90 minutes - April 2014

and multirisk

Toxic cabinets

08/2019

Pesticide range

R5132-66/68 of health regulation

cabinets - Ventilation

Fume hoods, filtering

Containment and Cans

SECUMAX90  + 1x E48

Anti-fire quipments and File cabinets

INCLUDED: • TestedandcertifiedaccordingtoEN14470-1F90 cabinets • (1) Ventilation/Filtration system and retention capacity of the charcoal filter tested and certified according toNF X 15- 211-may 2009 (universal (2) active charcoal filter included)

 FIRERESISTANCEOF105MIN  HEALTHY AND ENVIRONMENTALLY SAFE  PURIFIED FUMES  EASY TO INSTALL  ORGANIZEDSTORAGEBYCHEMICALSFAMILIES  INCERTIFICATIONWITHPUBLICHEALTHREGULATIONS  BETTER FINDING OF POSSIBLE LEAKS  SAFE PRODUCTS AGAINST MALEVOLENTLY  HAZARDS IDENTIFICATION

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid quipments

• Multi-chemicals storage • 4 separate compartments • 4 Containment shelves and 4 sumps • Key locking • Normalized labels

(1) The latest generation «CORG» filter adsorbs a large majority of chemicals commonly used in laboratories : organic and inorganic acids, solvents and organics.

8

Flammable cabinets

cabinets

Corrosive

EN 14470-1 & EN 14470-2 SAFETY CABINETS FOR FLAMMABLE AND EXPLOSIVE PRODUCTS, AND GAS CYLINDERS - - -

and multirisk

Toxic cabinets

Pesticide range

cabinets - Ventilation

Fume hoods, filtering

Containment and Cans

Anti-fire equipments and File cabinets

Showers and first- aid equipments

9

EN 14470-1 SAFETY CABINETS FOR FLAMMABLE AND EXPLOSIVE PRODUCTS EN 14470-2 SAFETY CABINETS FOR GAS CYLINDERS

Flammable cabinets

cabinets

INTRODUCTION For security reasons you have to store your flammable or explosive products in a safety cabinet. No matter your business branch or the degree of flammability of your products, they have to be stored in case of fire in order to delay the risk of explosion.

Corrosive

NORM

EN 14470-1 EN 14470-2

EN 14470-1 and 14470-2 EUROPEAN NORM :

Scope

and multirisk

Toxic cabinets

EN 14470-1: The new European norm came into effect in October 2004 and concerns the storage of flammable products in laboratories. It also only concerns the safety cabinets which internal volume is equivalent or less than 1m 3 . EN 14470-2 : The new European normcame into effect in April 2006 and concerns the storage of gaz cylinders in laboratoiries. It also only concerns the safety cabinets witch total internal volume allows storage gaz cylinders in a lower capacity 220 liters. FM ( FACTORY MUTUAL) : Offers worldwide industrial and commercial product certifiaction and testing services through its business unit FM Approvals. Recognized and respected across the worldwide, FM Approvals certification assures customers that a product or service has been objectively tested and conforms to the hightest ntaional and international standards. The certifaction FM requires a fire-resistance of 10 minutes for Safety cabinets, according to the heat curve NFPA 251-1969

08/2019

Pesticide range

Main requirements

1. Fire protection : In case of fire, the safety cabinet shall assure for at least 15 minutes that the contents of the cabinet do not contribute to any additional risks or spread of fire. A fire safety storage cabinet shall be classified as one of the types listed below:

EN 14470-2 Storage of gas cylinder

EN 14470-1 Storage of flammable liquids

Fire resistance

cabinets - Ventilation

Fume hoods, filtering

Type 15

Type G15

15 minutes

Type 30

Type G30

30 minutes

Type 60

Type G60

60 minutes

Type 90

Type G90

90 minutes

Containment and Cans

2. Fire test : All cabinets described in this brochure have succeeded a fire test destruction in according to EN 14770-1 (2004) or EN 14470-2 (2006) norms These tests were conducted by an outside laboratory accredited by COFRAC.

3. Spill containment sump : A spill containment sump shall be installed underneath the lowest storage level. The sump shall have: - a minimum capacity of 10% of the volume of all containers stored in the cabinet, - or at least, 110% of the volume of the largest single container, whichever is the greater.

File cabinets

4. Construction : The doors of the cabinet must be fully self-closing from any position. The side and back walls must be of the same thickness and comparable construction. Requirements are given in respect of the construction of the cabinet and its capacity to resist fire conditions from the outside (Fire test given in ISO 834-1 and EN 1363-1).

Anti-fire equipments

5. Safety labelling : Cabinets must be fitted with its signage: standardized pictograms in as per standard ISO 3864:

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid equipments EN 14470-1 : flammable materials, open flame and smoking prohibited, permissible maximum load per shelf, the largest container can be inserted into the cabinet, fire resistance model (15, 30, 60 or 90 minutes) capacity maintains closed when the cabinet door is not used ... EN 14470-2 : presence of compressed gas cylinders, fire resistance model (15, 30, 60 or 90 minutes), maintains cabinet doors closed when not in use. 6. Ventilation : Safety Cabinets must have air inlet and outlet as well as a thermo-fuse which seals off the ventilation system in case of fire. These could be used to connect a forced ventilation system. The air change must be at least 10 times the volume of the safety cabinet (closed doors).

10

Flammable cabinets

cabinets

Corrosive

 ISO 834-1 fire test curve

and multirisk

Toxic cabinets

07/2019

Pesticide range

 795 cabinet placed into the oven to fire test according to EN 14470-1 norm (photography before test).

 Sensors in a flammable cabinet

CHOOSE YOUR SAFETY CABINET ACCORDING TO YOUR ACTIVITY AND TO THE LEVEL OF PROTECTION YOU NEED

RECOMMENDED SAFETY CABINETS

DEGREE OF FLAMMABILITY

EXEMPLE OF PRODUCTS

FLASH POINT (1)

cabinets - Ventilation

Fume hoods, filtering

In Industries (2)

In laboratoiries

RANGE 3030, 7030, 1, 2 RANGE 3030, 7030, 1, 2, 3

LITTLE FLAMMABLE

RANGE 3030, 7030

HIGHER THAN 55°C

FUEL, GAS OIL

BETWEEN 21°C AND 55°C

OIL OF TURPENTINE, WHITE SPIRIT

RANGE 3030, 7030

FLAMMABLE

Containment and Cans

BETWEEN 0°C AND 21°C EASILY FLAMMABLE ETHANOL, METHANOL RANGE 760+, 2, 5

RANGE 760+

EXTREMELY FLAMMABLE

RANGE 790+

RANGE 790+

UNDER 0°C

ACETONE, ETHER

Gas cylinders model B2, B5, B11, B20 et B50

RANGE 7630BG

RANGE 7630BG

(1) Flash point : Lowest temperature at which a liquid could formgas/air mixtures able to burn when an ignition source is applied. (2) Please check our brochure Safety cabinets for flammables.

File cabinets

IN THIS PART OF THE CATALOG YOUWILL FIND:

Anti-fire equipments

Safety cabinets - 105 minutes

EN 14470-1, FM Range 790+ EN 14470-1, FM Range 790+T EN 14470-1, FM Range 790+ARD

Safety drawer cabinets - 105 minutes

Safety cabinets for recovery waste - 105 minutes

Multirisk cabinets - 105 minutes

EN 14470-1

Range 790+M Range 790+LI Range 760+

Storage cabinets for lithium-ion batteries - 105 minutes

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid equipments

Safety cabinets - 60 minutes

EN 14470-1

Safety cabinets - 30 minutes and 15 minutes Safety cabinets - 30 minutes and 15 minutes Type 30 minutes cabinets with glass doors

EN 14470-1, FM Range 3030 EN 14470-1, FM Range 3030.T

EN 14470-1 EN 14470-1 EN 14470-2

Range 3030PV Range 3030.M Range 7630BG

Multirisk cabinets - 30 minutes Safety cabinets for gaz cylinders

11

EN 14470-1 & FM (1) SAFETY CABINETS TYPE 105 MIN FOR FLAMMABLE PRODUCTS RANGE 790+ EN 14470-1 EN 1363-1 FM 6050

Flammable cabinets

cabinets

Corrosive

Standardized labeling

Self-closing door(s) with thermo-fuse

and multirisk

Toxic cabinets

Containment Shelf

Key locking System

08/2019

Pesticide range

 795+E + C235

Moving by pallet truck (empty)

Removable base through

cabinets - Ventilation

Fume hoods, filtering

CERTIFICATION - Tested and approved according to EN 14470-1 (04/2004) and EN 1363-1 (06/2000) type 90. - Normalized labelling according to ISO 3864 and EN 14470-1 (04/2004) norms, and 92/58/CEE european directive. - (1) Tested and approved Type 10 minutes according to FM 6050 (Factory Mutual internationnal). ADVANTAGES - Fire resistance for 105 minutes (approved Type 90) in as per ISO 834 fire heating curve. - Tested and approved by an independent European laboratory. PASSIVE SECURITY - Double wall construction : • Outer housing made of sheet steel (12/10th) with high quality epoxy coating RAL 9010. • Inner body built in white (RAL 9010) melamine-based wood. - Thermal insulation panel between the walls avoiding thermal bridges. - Removable bottom containment sump.

- In case of fire, a thermo-fuse automatically seals off the ventilation system. - Thermo-expanding seals of the door(s) allow keeping the internal body fireproof. - Separately locking door(s) with cylinder locks. - Self-closing door(s) with option to keep the door(s) open. If the temperature rises to 47°C, a fuse link closes the door(s) automatically. OPTIONS - Doors with different color possibility for 794 and 795 models: • Frame and shelves in white (RAL 9010); doors in yellow (RAL1023) - Additional shelf - Grating for retention tank - Drawer / sliding retention tray - PVC surprotections - Ventilation or filter casings - Absorbent mats to be placed at the bottom of the holding tank (packets of 10 sheets) - Code lock (1 per door)

Containment and Cans

File cabinets

Anti-fire equipments

- Safety labellings as per EN 14470-1. - Adjustable containment shelves. - Earthing link.

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid equipments

Cooling system

To increase the security of your cabinet and control the temperature inside, we propose you a cooling system. Ask-us for more information.

ACTIVE SECURITY - Ø 100 mm air inlet and outlet ducts for whether natural ventilation or connection with forced ventilation/filtration system.

12

EN 14470-1 EN 1363-1 FM 6050

RANGE 790+

Flammable cabinets

 Option Code lock (1 per door)

cabinets

Corrosive

794+E + C148 

795+EJ 

CABINETS WITH EQUIPMENTS

Delivered with

Number of door(s)

Outside dimensions H x W x D (mm) 630 x 635 x 570 (1) 630 x 635 x 570 (1)

Storage capacity (L)

Door’s reference

Weight (kg)

Maximum load by shelf (kg)

Description

Type

Containment shelf

Containment sump

white

yellow

- - - - - - -

Cabinet equipped under-bench Cabinet equipped under-bench Cabinet equipped under-bench Cabinet equipped under-bench Cabinet equipped working cover Cabinet equipped working cover

1 1

30 30 60 60

1

1 1 1 1 1 1 1 1 1

30 30 50 50 30 40 50 30 50

127 155 213 240 297 182 287 453 438

791+E (1) 791T+ (1) 792+E (1) 792T+ (1) 793+E (2) 798+E (2) 794+E (3) 795+E (3)

-

2 630 x 1137 x 570 (1) 1 630 x 1137 x 570 (1) 2 1100 x 1137 x 670 (2) 1 1100 x 635 x 670 (2) 1 1950 x 635 x 620 (3) 2 1950 x 1137 x 620 (3) 2 1950 x 905 x 620 (3)

1

-

and multirisk

Toxic cabinets

115 65 130 250 200

2 2 3 3 3

Cabinet equipped

tall tall tall

794EJ (3) Cabinet equipped

795-900+E (3) 795EJ (3) Cabinet equipped

07/2019

NON-EQUIPPED CABINETS

Pesticide range

Outside dimensions H x W x D (mm) 630 x 635 x 520 (1) 630 x 1137 x 520 (1) 1100 x 1137 x 620 (2) 1100 x 635 x 620 (2) 1950 x 635 x 620 (3)

Inside dimensions H x W x D (mm) 420 x 490 x 285 420 x 1000 x 285 820 x 1000 x 410 820 x 490 x 410 1620 x 490 x 410

Number of door(s)

Weight (kg)

Reference

Description

Type

122 203 277 171 277 435 420

791+ 792+ 793+ 798+ 794+ 795+

Cabinet without equipment Cabinet without equipment Cabinet without equipment Cabinet without equipment Cabinet without equipment Cabinet without equipment Cabinet without equipment

under-bench under-bench working cover working cover

1 2 2 1 1 2 2

tall tall tall

1950 x 1137 x 620 (3) 1620 x 1000 x 410

795-900+

1950 x 905 x 620 (3)

1620 x 765 x 410

cabinets - Ventilation

Fume hoods, filtering

CABINETS WITHOUT EQUIPMENTS AND ACCESSORIES

Outside dimensions H x W x D (mm) 30 x 490 x 380 30 x 1000 x 380 30 x 490 x 410 30 x 1000 x 410 30 x 765 x 410 100 x 490 x 380 100 x 1000 x 380 100 x 490 x 410 100 x 1000 x 410 100 x 765 x 410 90 x 480 x 380 90 x 990 x 3800 90 x 460 x 390 90 x 990 x 400 90 x 755 x 400 80 x 430 x 390 80 x 940 x 390 80 x 420 x 380 80 x 930 x 380 80 x 695 x 380 30 x 488 x 377 100 x 471 x 409 235 x 640 x 620 235 x 1140 x 620

Weight (kg)

P/N

Description

E1 E2

Containment shelf for 1 door cabinet type 791+ Containment shelf for 1 door cabinet type 792+

Containment and Cans

3 6 6

E48 E35

Containment shelf for 1 door cabinet - W: 635 – D: 615 mm (1) Containment shelf for 2 doors cabinet - W: 1135 – D: 615 mm Containment shelf for 2 doors cabinet - W: 900 – D:615 mm Containment sump for 1 door cabinet type 791+ Containment sump for 2 doors cabinet type 792+ Containment sump for 1 door cabinet - W: 635 – D: 615 mm Containment sump for 2 doors cabinet - W: 1135 – D: 615 mm Containment sump for 2 doors cabinet - W: 900 – D:615 mm Perforated cover plate for 1 door cabinet type 761+ Perforated cover plate for 2 doors cabinet type 762+ Perforated cover plate for 1 door cabinet - W: 635 - D: 615 mm Perforated cover plate for 2 doors cabinet - W:1135 - D: 615 mm Perforated cover plate for 2 doors cabinet - W:900 - D:615 mm Perforated cover plate for 1 door drawer cabinet Perforated cover plate for 1 door drawer cabinet Self retracting shelf for 1 door cabinet - W: 635 mm - D: 615 mm Self retracting shelf for 2 doors cabinet - W:1135 mm - D:615 mm Self retracting shelf for 2 doors cabinet - W:900 mm - D:615 mm PVC containment shelf for E79148 (for E79235 model, 2 pieces by level are required) PVC Containment sump for 1 door cabinet in W: 615 mm. For 2 doors models in W: 1135, 2 pieces by level are required).

E235-900

B1 B2

B48 B35

5

10 10

B235-900

File cabinets

C1 C2

Anti-fire equipments

C48 C35 C1T C2T T48 T35

4 8 8 8 8 6

C235-900

12 12

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

T235-900

Showers and first- aid equipments

SE48 SB48 TP48 TP35

3 5

Sloping roof for cabinet 1 door cabinet Sloping roof for cabinet 2 doors cabinet

10 20

SERVICODE

Code lock ((1 per door)

(1) Depth with the connecting sleeve at the back. Depth without connecting sleeve : 520 mm (2) Depth with the connecting sleeve at the back. Depth without connecting sleeve : 620 mm (3) Height with the connecting sleeve at the back. Height without connecting sleeve : 1900 mm

13

RANGE 790+T EN 14470-1 EN 1363-1 FM 6050

EN 14470-1 SAFETY CABINETS TYPE 105 MIN FOR FLAMMABLE PRODUCTS WITH SELF ERGONOMIC RETENTION DRAWERS

Flammable cabinets

cabinets

Corrosive

and multirisk

Toxic cabinets

07/2019

Pesticide range

cabinets - Ventilation

Fume hoods, filtering

 795+T6

794+T5  Self retracting drawer with automatic closing in case of fire (1)

Containment and Cans

792T+ 

File cabinets

Anti-fire equipments

Outside Dimensions H x W x D (mm)

Inside Dimensions H x W x D (mm)

Number of doors

Weight (kg)

P/N

Description

Type

791T+ 792T+ 794+T4 794+T5 794+T6 795+T4 795+T5 795+T6

Cabinet 1 drawer Cabinet 1 drawer

under-bench under-bench

1 1 1 1 1 2 2 2 2 2

630 x 635 x 520 450 x 480 x 370 155 630 x 1137 x 520 450 x 950 x 370 240 1900 x 635 x 620 1620 x 490 x 410 301 1900 x 635 x 620 1620 x 490 x 410 307 1900 x 635 x 620 1620 x 490 x 410 313 1900 x 1137 x 620 1620 x 1000 x 410 483 1900 x 1137 x 620 1620 x 490 x 410 495 1900 x 1137 x 620 1620 x 1000 x 410 507

Cabinet 1 door, 4 drawers Cabinet 1 door, 5 drawers Cabinet 1 door, 6 drawers Cabinet 2 doors, 4 drawers Cabinet 2 doors, 5 drawers Cabinet 2 doors, 6 drawers Additional drawer 1 door (1) Additional drawer 2 doors (1)

tall tall tall tall tall tall tall tall

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid equipments

T48 T35

80 x 420 x 380 80 x 930 x 380

- -

6

12

14

(1) To be ordered during manufacture. Maximum quantity per cabinet: 6

EN 14470-1 SAFETY CABINETS FOR RECOVERY OF WASTE - TYPE 90 MINUTES EN 14470-1 EN 1363-1 RANGE 790+ARD

Flammable cabinets

cabinets

Corrosive

Electronic level sensor

Audible and visual alarm

and multirisk

Toxic cabinets

08/2019

Pesticide range

Waste container

Funnel on draining board

791ARD  (draininig board not included)

Safety cabinet Type 90 minutes

cabinets - Ventilation

Fume hoods, filtering

EN14470-1UNDER-BENCHCABINETS -TYPE 90MINUTES CERTIFICATION - Tested and approved according to EN 14470-1 (04/2004) and EN 1363-1 (06/2000). - Normalized labelling according to ISO 3864 and EN 14470-1 (04/2004) norms, and 92/58/CEE european directive. ADVANTAGES - 90-minute fire resistance according to ISO 834 fire heating curve. - Tested and approved by an independent European laboratory. PASSIVE SECURITY - Wall building with double layers : • Building’s outer walls and doors are of sheet of steel (12/10 th ) with high quality epoxy coating RAL 9010; • Inner body built in melamine-based wood. - Removable retention tank located at the bottom of the cabinets. - Safety labellings with standardized labels. - Earthing link.

ACTIVE SECURITY - Ø 100 mm air inlet and outlet ducts for whether natural ventilation or connection with forced ventilation/filtration system. - Ventilation pipes, equipped with expandable seals. - Self-closing door(s) with possibility to keep the door(s) open. - Self-closing device of the door(s) at 47°C. - Drilling located on the roof of the cabinet for the evacuation pipe, including a thermo-expandable system to protect contents in the cabinet against fire. This drilling could change the fire resistance. - Funnel, made of black HDPE, is equipped with grating, which allows to get back liquid wastes. - Can is made of white HDPE - 10 liters (size of the can : 265 x 185 x 290). - An electronic level sensor is fixed with a velcro strip on the can or on the cabinet. - A visual and sound system alarm can be installed on sides of the cabinet. RECOVERY OF WASTE SYSTEM

Containment and Cans

File cabinets

Anti-fire equipments

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid equipments

Outside dim. H x W x D (mm)

Inside dim. H x W x D (mm)

W. (kg) 160 230

Base trough

P/N

Description

791ARD Under-bench cabinet for recovery of waste - One door 792ARD Under-bench cabinet for recovery of waste - Two doors

630 x 635 x 520 420 x 490 x 285 630 x 1137 x 520 420 x 1000 x 285

1 1

15

EN 14470-1 MULTIRISK CABINETS – 105 MINUTES RANGE790+M EN 14470-1 EN 1363-1

Flammable cabinets

cabinets

Corrosive

Self-closing door(s) with thermo-fuse

Standardized labeling

and multirisk

Toxic cabinets

07/2019

Pesticide range

Containment shelf

Key locking System

cabinets - Ventilation

Fume hoods, filtering

Moving by pallet truck (empty)

Removable base Trough

 795+M22 + 1x E48

Containment and Cans

CERTIFICATION - Tested and approved according to EN 14470-1 (04/2004) and EN 1363-1 (06/2000). - Normalized labelling according to ISO 3864 and EN 14470-1 (04/2004) norms, and 92/58/CEE european directive. ADVANTAGES - Fire resistance for 90 minutes (approved Type 90) as per ISO 834 fire heating curve. - Tested and approved by an independent European laboratory. - Possibility to separate the dangerous products families. PASSIVE SECURITY - Double wall construction : • Outer housing made of sheet steel (12/10 th ) with high quality Epoxy coating RAL 9010. • Inner body built in white (RAL 9010) melamine-based wood. - Thermal insulation panel between the walls avoiding thermal bridges. - Removable bottom containment sump.

ACTIVE SECURITY - Ø 100 mm air inlet and outlet ducts for whether natural ventilation or connection with forced ventilation/filtration system. - In caseof fire, a thermo-fuse automatically seals off the ventilation system. - Thermo-expanding seals of the door(s) allowkeeping the internal body fireproof. - Separately locking door(s) with cylinder locks. - Self-closing door(s) with possibility to keep the door(s) open. If the temperature rises up to 47°C, a fuse link closes the door(s) automatically. OPTIONS - Doors with different color possibilities on 794+M and 795+M models (see documentation for Range 7.90) : • Frame and shelves inwhite (RAL 9010) ; doors in yellow (RAL1023) - Code lock (1 per door)

File cabinets

Anti-fire equipments

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid equipments

- Safety labellings as per EN 14470-1. - Adjustable containment shelves. - Earthing link.

16

EN 14470-1 EN 1363-1

RANGE790+M

Flammable cabinets

Vertical/horizontal division

Containment shelf

Containment sump with perforated cover plate

Containment sump

cabinets

Corrosive

 792+M11

 793+M11

 793+M12

 795+M11

 795+M12

and multirisk

Toxic cabinets

07/2019

Pesticide range

 798+M2

 794+M2

 794+M3

 794+M4

 795+M13

 795+M22

CABINETS WITH EQUIPMENTS

Compartment type and storage capacity (L) (1)

Maximum load by shelf (2) (kg)

Delivered with

Weight (kg)

P/N

Description

HxWxD(mm)

cabinets - Ventilation

Fume hoods, filtering

Containment shelf

Containment sump

Perforated coverplate

ACIDS

BASES

792+M11 Under-bench cabinet, two doors, with 2 compartments 793+M11 Working cover cabinet, two doors, 2 compartments 793+M12 Working cover cabinet, two doors, 3 compartments 794+M2 Tall cabinet, one door, with 2 compartments 794+M3 Tall cabinet, one door, with 3 compartments 794+M4 Tall cabinet, one door, with 4 compartments 795+M11 Tall cabinet, two doors, with 2 compartments 795+M12 Tall cabinet, two doors, with 3 compartments 795+M13 Tall cabinet, two doors, with 4 compartments 795+M22 Tall cabinet, two doors, with 4 compartments

28 28 - 55 55 -

- -

630 x 1137 x 570 (1) 1100 x 1137 x 670 (2) 1100 x 1137 x 670 (2) 1100 x 1137 x 670 (3) 1100 x 635 x 670 (2) 1950 x 635 x 620 (3)

2 2 1

2 2 3 2 2 3 4 2 3 4 4

option

30 30 30 30 30 30 30 30 30 30 30

221 311 317 194 304 307 320 477 486 489 497

2 3 2 2

55 28 28 -

798+M2 Working cover cabinet, one door, 2 compartments 28 28 -

- -

-

Containment and Cans

55 55 -

2 3

30 30 30 -

option

22 22 22 22 1950 x 635 x 620 (3)

-

4

120 120 -

-

6 5 6 4

option

1950 x 635 x 620 (3) 1950 x 1137 x 620 (3)

120 55 55 -

2

120 28 28 28 1950 x 1137 x 620 (3) 55 55 55 55 1950 x 1137 x 620 (3)

option

4

(1) Compartments customization on request (2) Evenly distributed

File cabinets

ACCESSORIES

Anti-fire equipments

Dimensions H x W x D (mm) 30 x 490 x 410 100 x 490 x 410 90 x 460 x 390 80 x 420 x 380 30 x 485 x 405 100 x 485 x 405

Weight (kg)

P/N

Description

E48 Containment shelf for 792M11, 793M1x, 798M2, 794Mx, 795Mxx cabinets B48 Containment sump for 792M11, 793M1x, 798M2, 794Mx, 795Mxx cabinets C48 Perforated cover plate for 792M11, 793M1x, 798M2, 794Mx, 795Mxx cabinets T48 Self retracting shelf for 792M11, 793M1x, 798M2, 794Mx, 795Mxxn cabinets

3 5 5 6 2 3

The manufacturer reserves the right to discontinue or change specifications or designs at any time without notice and without incurring obligations.

Showers and first- aid equipments

SE48 PVC containment shelf for E79148 shelf for 792M11, 793M1x, 798M2, 794Mx, 795Mxx cabinets SB48 PVC containment sump for 792M11, 793M1x, 798M2, 794Mx, 795Mxx cabinets

(1) Depth with connecting sleeve at the back. Depth without sleeve: 520 mm (2) Depth with the connection sleeve at the back. Depth without sleeve: 620 mm (3) Height with the connection sleeve above. Height without sleeve: 1900 mm

N.B. : In compliance with the EN14470-1 norm and for the extraction of toxic vapours generated inside your cabinet, an exhausting system is required. In all cases, before storing chemical products in combined risks cabinets, each user must contact his safety manager and his chemical products supplier. Please, check our documentation about exhausting systems.

17

Made with FlippingBook Publishing Software