Bullard SALUS HC Tech Specs

1898 Safety Way BULLARD

CYNTHIANA, KY 41031 USA 877-BULLARD (285-5273)

THESE RESPIRATORS ARE APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS: MODEL SALUS HC SERIES POWERED AIR PURIFYING RESPIRATORS

RESPIRATOR COMPONENTS

BREATHING TUBE

BLOWER ASSEMBLY

FILTER ASSEMBLY BATTERY CHARGER

CARRIAGE ASSEMBLY CAUTIONS AND LIMITATIONS 2

PROTECTION 1

TC-

ALTERNATE HOOD ASSEMBLIES

20LFL

20LFM

20LF2L

20LF2S

20LFXL

20LF2M

SALHC1

20LFLHE

20LFMHE

PAPRFC6

SALHCBT

20LFXLHE

SALHCBAT

SALHCBC1

SALHCCAR

21C-1235 21C-1236 21C-1237

PAPR100-P PAPR100-P PAPR100-P

X X X

ABCFIJLMNOP ABCFIJLMNOP ABCFIJLMNOP

X X X

X X X

X X X

X X X

X X X

X X X

X X X

X X X

1 PROTECTION PAPR100-P - PAPR100-P Particulate Air Filter for Powered, Air Purifying Respirators

2 CAUTIONS AND LIMITATIONS A. Not for use in atmospheres containing less than 19.5 percent oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentrations established by regulatory standards. F. Do not use Powered Air-Purifying Respirators if airflow is less than four cfm (115 lpm) for tight-fitting facepieces or six cfm (170 lpm) for hoods and / or helmets. I. Contains electrical parts that may cause an ignition in flammable or explosive atmospheres. J. Failure to properly use and maintain this product could result in injury or death. L. Follow the manufacturer's User Instructions for changing cartridges, canister and / or filters. M. All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations. N. Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration specified by the manufacturer. O. Refer to User Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P. NIOSH does not evaluate respirators for use as surgical masks.

1898 Safety Way BULLARD

CYNTHIANA, KY 41031 USA 877-BULLARD (285-5273)

PAPRFC6 FILTER THIS FILTER IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:

RESPIRATOR COMPONENTS

BREATHING TUBE

BLOWER ASSEMBLY

FILTER ASSEMBLY BATTERY CHARGER

CARRIAGE ASSEMBLY CAUTIONS AND LIMITATIONS 2

PROTECTION 1

TC-

ALTERNATE HOOD ASSEMBLIES

20LFL

20LFM

20LF2L

20LF2S

20LFXL

20LF2M

SALHC1

20LFLHE

20LFMHE

PAPRFC6

SALHCBT

20LFXLHE

SALHCBAT

SALHCBC1

SALHCCAR

21C-1235 21C-1236 21C-1237

PAPR100-P PAPR100-P PAPR100-P

X X X

X X X

X X X

X X X

X X X

X X X

X X X

ABCFIJLMNOP ABCFIJLMNOP ABCFIJLMNOP

X X X

X X X

1 PROTECTION PAPR100-P - PAPR100-P Particulate Air Filter for Powered, Air Purifying Respirators

2 CAUTIONS AND LIMITATIONS A. Not for use in atmospheres containing less than 19.5 percent oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentrations established by regulatory standards. F. Do not use Powered Air-Purifying Respirators if airflow is less than four cfm (115 lpm) for tight-fitting facepieces or six cfm (170 lpm) for hoods and / or helmets. I. Contains electrical parts that may cause an ignition in flammable or explosive atmospheres. J. Failure to properly use and maintain this product could result in injury or death. L. Follow the manufacturer's User Instructions for changing cartridges, canister and / or filters. M. All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations. N. Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration specified by the manufacturer. O. Refer to User Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P. NIOSH does not evaluate respirators for use as surgical masks.

SALUS HC diagram

Made with FlippingBook Annual report maker