AFA960001
KStrong First Man up telescopic pole allows the user to create an overhead anchor when there is no anchorage point available due to being out of reach. The telescopic poles reach allows the user to attach a rope line up to 10.5m above the user in complete safety.
Features
▪
Light, Flexible & Robust construction Telescopic extension 1.95m – 10.5m
HEAD
▪
HANGING HOOK
▪
Dielectric Resistance 30kV Interchangeable components No Maintenance required
▪
▪
▪
Simple connection between Pole and Aluminum hook
▪
Easy to carry
▪
Secure Locking System
▪
Comes in a backpack style carry bag
How To Use
TELESCOPIC POLE
Refer to User Instruction Manual
EXTENSION SECTION
Material
Pole, Head & Extension Piece ▪ Fiberglass ▪ Plastic Molded Nut
Hanging Head ▪
Alloy Steel, with Plastic mould
Anchorage Hook ▪
Aluminum MBS 22 kN
Stitching Thread
Telescopic Pole (AFA960001)
: 1.95 m – 7.95 m
Extension Pole (AFA960002)
: 1.0 m
Head (AFA960003)
: 240 mm
Total Reach (AFA960004)
: 10.5 m
ALUMINUM ANCHORAGE HOOK (AFC608410)
Ref. No. PN 815
Rating
Dielectric Resistance
: 30 kV
Weight
4.6 kg (Without Aluminum Anchorage Hook) 5.08 kg (With Aluminum Anchorage Hook) 4.6 kg (Without Aluminum Anchorage Hook) 5.08 kg (With Aluminum Anchorage Hook) 4.6 kg (Without Aluminum Anchorage Hook) 5.08 kg (With Aluminum Anchorage Hook)
THESE INSTRUCTIONS APPLY TO THE FOLLOWING MODEL: IRSQ TELESCOPIC POLE USER INSTRUCTION MANUAL AFA960001 with AFC608410
1. INTRODUCTION: IRSQ Telescopic Pole is a perfect solution to create overhead anchors at unreachable heights. It can be effectively used to install an anchorage point from a distance. The IRSQ Telescopic Pole is designed to create temporary overhead anchorages with help of Rebar hook assembled to it at the extreme end. Always remember that care must always be taken while carrying out the risk related activity. 2. APPLICATION: Can be effectively used to install an anchorage point from a distance during the time of rescue. 3. INSPECTION: Visually inspect the system before each use to ensure that it is in a serviceable condition and is operating correctly. If during inspection, doubts are raised about the safety of the system or a component, these should be replaced either by the manufacturer or a competent person. 4. PRECAUTIONS: Avoid use of IRSQ Telescopic Pole under following hazardous conditions, as it may affect the performance of the product:- Ÿ Ensure that the IRSQ Telescopic Pole is compatible with other items when assembled into a system. Ÿ Usage with other non-compatible items may be dangerous & hazardous as the safe function of one item may be affected or interferes with the safe function of another. Ÿ Extreme temperatures. Ÿ Trailing or looping of Lanyards over sharp edges. Ÿ Extreme acidic or basic environments. Ÿ Abrasive or sharp edge structures which can damage the equipment. Ÿ A rescue plan should be in place to deal with any emergencies that could arise during the work. 5. PRE USE CHECK : The pre use check shall involve checking of any wear or abrasion on ropes and sign of corrosion, if any, on metal parts or any breakage of the plastic/aluminium part. 6. INSTRUCTIONS FOR USE: Follow below steps to use this equipment:- Insert the Rope through the captive eye of the Anchorage Hook and terminate it either with a suitable knot or stitching. Please read and understand the manufacturer's instructions for each component or part of the complete system. Manufacturer's instructions must be followed for proper use, care, and maintenance of this product. These instructions must be retained and be kept available for the user's reference at all times. Alterations or misuse of this product, or failure to follow instructions, may result in serious injury or death. Note: The user is advised to keep this user instructions document for the life of the product. IRSQ Telescopic Pole
Hanging Hook Head
SCAFFOLD/ STRUCTURE
SCAFFOLD/ STRUCTURE
Tested in Directions
PULL HAND
Now insert the hanging hook of IRSQ Telescopic Pole into the Lock Ring of the Anchorage Hook.
Adjust the length of IRSQ Telescopic Pole as per the height of the structure and insert the Nose of the Anchorage hook into the structure and slowly release hanging hook from Anchorage Hook. Once hanging hook is pulled back, the Lock of Anchorage hook will lock automatically under spring action. Now, the Anchorage is ready to use.
01
Ÿ To Extend Pole:- Rotate the locking lever into open position, hold outer section and pull inner pole to desired length and lock the extended position by rotating back the locking lever into locked position. To Retract Pole:- Rotate the locking lever into open position, hold the outer section and slide inner section into outer section and rotate back the locking lever into locked position. Collapse pole to shortest length for storage. 7. ANCHORAGE STRENGTH: Ensure that the strength of the anchor structure is greater than 12kN. 8. LIMITATIONS : Ÿ This IRSQ Telescopic pole cannot be used as a part of a fall arrest system or as a part of a restraint system. Ÿ It has a maximum dielectric resistance of 30kV. Ÿ The IRSQ Telescopic pole should be the personal property of the user. Ÿ The IRSQ Telescopic pole shall not be used outside its limitation, or for any purpose other than that for which it is intended. Ÿ Label on AFA960001 AFA960001 Ÿ
Ÿ Ensure that manufacturer's packing is used during transportation to prevent damage. In case original packing is not available, use polybag which is sealed to prevent moisture. Ÿ It is essential for the safety of the user that if the product is resold outside the original country of destination, the reseller shall provide instruction for use, for maintenance, for periodic examination and for repair in the language of the country in which product is to be used. 9. REPAIR: If the product becomes damaged, it will NOT provide the optimum level of protection, and therefore should be immediately removed from service. It needs to be inspected to see if it is replaced or repaired. Never use the damaged product. Repair is only permitted by the manufacturer or a nominated repair centre or individual approved by the manufacturer. 10. INSTRUCTION FOR MAINTENANCE & STORAGE: Follow the maintenance instructions procedure laid below strictly. In case of minor soiling, wipe the equipment with cotton cloth or soft brush. Do not use any abrasive material. For intensive cleaning wash in water at a temperature between 0 0 25 C to 50 C using a neutral detergent. It should be allowed to dry by itself and be kept away from open fire or any other source of heat. Avoid direct sunlight. Store in cool dry place, preferably away from moisture, direct sunlight, extra acidic or basic conditions, and sharp edges. WARNING: Ÿ Do not make any alterations or additions to the IRSQ Telescopic pole without the manufacturer's prior written consent. 11. Ÿ
MARKING ON :- AFC608410 AFC608410 CE 0598 22KN KSTRONG EN 795:2012 TYPE B & EN 362:2004 CLASS A (i) (ii) (iii) (iv) (v) (vi)
MARKING EXPLANATION: The Connector is marked with :
i)
Type or product code.
ii)
The CE mark showing that the product meets the requirements of the PPE Regulation (EU) 2016/425
iv) iii)
Identification of the manufacturer. Minimum Breaking Strength . EN Norms to which it complies.
v)
vi)
Read Instructions Carefully.
02
LIFESPAN: The estimated product Lifespan is 10 years from the date of manufacture. The following factors can reduce the Lifespan of the product: intense use, contact with chemical substances, specially aggressive environments, extreme temperature exposure, UV exposure, abrasions, cuts, violent impacts, bad use or maintenance. DISCLAIMER: Prior to use, the end user must read and understand the manufacturer's instructions supplied with this product at the time of shipment and seek training from their employer's trained personnel on the proper usage of the product. Manufacturer is not liable or responsible for any loss, damage or injury caused or incurred by any person on grounds of improper usage or installation of this product.
EQUIPMENT RECORD
Product Model & type/Identification
Trade Name
Identification number
Tel, email into use
Address
Manufacturer
Date first put into use
Purchase Date
Year of manufacture
Other relevant information (eg. document number)
PERIODIC EXAMINATION AND REPAIR HISTORY
Date
Name and signature of competent person
Periodic examination next due date
Reason for entry (periodic examination or repair)
Defects noted, repairs relevant information carried out and other
For EU Declaration, please visit https://kstrong.com/asia/eu-declaration-form/
KStrong Inc. 150 N. Radnor Chester Road Suite F200 Radnor, Pennsylvania 19087 United States Contact number : 1-833-KSTRONG Contact Email: customercare@kstrong.com
AKS- - AFA960001 290721-v2
www.kstrong.com
USA
ASIA
South America
Declaration of Conformity
In accordance with European PPE Regulation (EU) 2016/425
Declaration Number: KSDC2749
Revision: 00
Manufacturer name and address: 150 N. Radnor Chester Road, Suite F200 Radnor , State : PA,Pin-19087. Product Information: AFA960001 KSTRONG TELESCOPIC POLE HEAD Product Reference: AFA960001 Manufacturer declares that the product listed above is in conformity with the requirements of the following standard(s): • Standard(s) to which product was tested and for which conformity is claimed, designation and year. EN 795:2012 & ANSI Z359.1:2007 • ISO 17025-accredited test laboratory address and contact information: SATRA Technology Europe Ltd, Bracetown Business Park, Clonee, Dublin D15 YN2P Ireland (Notified Body 2777) • Ongoing Assessment Body: SGS Fimko Oy, Takomotie 8, FI-00380 Helsinki, Finland (Notified Body 0598) • Certificate / Test report(s) Reference: spc0224408/1418 issue 2
Authorized Signatory Mr. Gary Gill Managing Director 01/04/2021